4. The dehumidifier must be installed on a level floor that will support it with a full bucket of 

    water.
5. There should be a minimum of 12 inches clearance around the dehumidifier. The unit will 

    produce heat while in operation and should not be operated in an enclosed small space like 

    a closet.

2. Place dehumidifier in a location that does not restrict the airflow of the air intake and air 

    outlet.
3. A dehumidifier operating in a basement will have little or no effect in drying an adjacent 

   enclosed storage area, such as a closet, unless there is adequate circulation of air in and out 

   of the area. lt may be necessary to install a second dehumidifier in the enclosed area for 

   satisfactory drying.

1. Dehumidifier must be operated in an enclosed area to be most effective. Close all doors, 

    windows, and other outside openings to the room. The effectiveness of the dehumidifier 

    depends on the rate at which new moisture-laden air enters the room.

Location

Selecting a Location

IMPORTANT:

How  It Works

When the unit  is started, the fan begins to pull moisture-laden air across the dehumidifying coils. 

The coils condense or draw moisture from the air, and air flows through the air outlet louvers into 

the room as dry, warm air. Moisture removed from air is collected in a  bucket on the front of the 

dehumidifier.

The "Compressor" circuit has an automatic 3 minute time delayed start if the unit is turned off 

and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. 
Make sure the tank is fitted correctly otherwise unit will not turn on.

The unit is designed to operate between 41 °F (5 °C), and 89 °F (32 °C). The unit will not work 

properly if the temperature is out of this temperature range, or the performance of the unit will 

fall greatly.

Wiring Diagram

DISPLAY

BOARD

MAIN  BOARD

FAN

POWER

CN10

CN1

CN3

CN5

P8

CN4

CN2

WATER

SWITCHTEMP.

PIPE HUMI.

SENSOR

BLACK(OR BROWN OR RED)(L)

RED

WHITE(OR BLUE OR BLACK)(N)

Y/G

Y/G(or  GREEN)

BLUE

BROWN

FAN

CAPACITOR

Y/G

M

C

S

M

~

COMP.

BLUE

This symbol 

indicates 

the element

is optional,

the actual 

shape shall 

prevail

Notes:

OverLoad

Protector

P7

P4

RED

BLACK

ION

Y/G

P10

(or CN6/CN6A/CN6B/CN6C/CN10)

(or CN13)

Notes: 

Display and Fan's conntors must be match the actual indicates

.

CN11

TOUCH/LIGHT

PANEL

POWER

 BOARD

CN1

CN2

CN14

CN15

1 3

1 2

3

1

1

2

CN7

SWITCH

P2 P1

CN10

WIFI

CN1

PUMP

DC  POWER

BOARD

CN2

RED

OPTIONAL

P9

P6

BLACK(or  BLUE)

BLACK(or BLUE)

WHITE

TOP

STEP

M

CN5

CN12

WIFI

1602010000

1654

COMP.

CAPACITOR

BLUE

BLACK

RED

CN6B

SWITCH

12"

Do not Block
at least 24"

12"

Содержание Gallery FGAC5044W10

Страница 1: ...res 5 Operating Instructions 5 10 Care And Cleaning 11 Storage 11 Normal Sounds 11 Before You Call 12 Major Appliance Limited Warranty 13 TABLE OF CONTENTS www frigidaire com USA 1 800 944 9044 www frigidaire ca Canada 1 800 265 8352 Use Care of your Dehumidifier All about the 16120100A13052 ...

Страница 2: ... grille discharge area and outlet ports Ensure that any electrical electronic equipment is one yard away from the unit Do not use or store flammable gases near the unit This dehumidifier contains no user serviceable parts Always call an authorized Electrolux servicer for repairs Do not insert or place fingers or objects into the air discharge area or back grille of the unit Do not start or stop th...

Страница 3: ...aw moisture from the air and air flows through the air outlet louvers into the room as dry warm air Moisture removed from air is collected in a bucket on the front of the dehumidifier The Compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping Make sure the tank is fit...

Страница 4: ... This equipment should be installed and operated with minimum 20 cm between the radiator and your body This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC RF exposure statement This Class B digital apparatus complies with Canadian ICES 003 This device complies with Industry Canada license exempt RSS standar...

Страница 5: ...gidaire app WIFI BUTTON SETS FAN SPEED BUCKET FULL INDICATOR SETS TIMER MODE BUTTON Refer to the Quick Start Guide that came with your Smart Dehumidifier for detailed instructions on setting up your dehumidifier for connected operation from your smart phone or tablet 5 2019 Electrolux Home Products Inc All rights reserved Situation Quick Glance Light Behavior In Quiet or Continuous mode The light ...

Страница 6: ...e unit to reach room temperature before operating To begin operating the dehumidifier follow these steps 1 Plug the power cord into a properly grounded 115 volt AC outlet If the BUCKET FULL light is flashing remove the bucket and re install to reset the float switch NOTE Unit must be upright for one hour prior to operating NOTE 3 To use Quiet mode press the Mode button to choos Quiet mode The unit...

Страница 7: ...TINUOUS mode when in Dry mode pressing the button until the display reads CO In this mode the unit will continuously on and the unit will only display CO not the room humidity To leave this mode press the button 5 During the Dry mode You can also use the FAN SPEED button to change the fan speed to Hi Med or Lo The indicator light will show the setting you have selected A higher fan speed will resu...

Страница 8: ...imer will turn the unit on in the hours that will be set Delay Start TIMER setting First press TIMER button then adjust timer setting by tapping or holding the or button to change the delay timer at 0 5 hour increments up to 10 hours then by 1 hour increments up to 24 hours The control will count down the time remaining 8 7 5 7 etc until the unit either starts or stops For the Delay Start the fan ...

Страница 9: ...n and the BUCKET FULL indicator will illuminate 3 If the display reads E4 the communication between display PCB and main control PCB is faulty Contact your Authorized Frigidaire Service Center b Do not move the unit at this time otherwise water may spill on the floor c Press sides of bucket gently to unclip the bucket from the unit d Remove the bucket as shown in the photographs below and empty th...

Страница 10: ...ard the drain making sure that there are no kinks that will stop the water flowing g Place the end of the hose into the drain fig 4 h Select the desired humidity setting and fan speed on the unit for continuous draining to start 1 Check the seal between the hose and the drain connector If there is a small leak then replace the hose gasket and re tighten the hose 2 It is recommended that a Dehumidi...

Страница 11: ...800 944 9044 US 1 800 265 8352 Canada 1 Filter Clean the filter every two weeks based on normal operating conditions To remove the filter a Open the back grille and pull out the filter b Wash the filter with clean water then dry c Re install the filter Normal Sounds may have a high pitched chatter Today s high efficiency compressors during the dehumidification cycle High pitched Chatter The sound ...

Страница 12: ...41 F 5 C See Operating Conditions Refer to causes under DEHUMlDIFIER RUNS TOO MUCH Dehumidifier has been turned on recently This is normal due to refrigerant rushing through the coil Frost will usually disappear within 60 minutes Room Temperature is too low All models will operate satisfactorily at temperatures greater than 41 F 5 C FAN NOISE Air is moving through the dehumidifier This is a normal...

Страница 13: ...UX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APP...

Отзывы: