Страница 1: ...SULT INSTALL ANTI T1P DEVICE PACKED wn14 RANGE SEE INSTALLAllON INSTRUCTIONS Note For appliances installed in the state of Massachusetts see page 2 RANGE OVERALL DIMENSIONS 253 4 44 5 8 Door Open MaximumDepth for Cabinets AboveRangeTop _25 _ 0 ClearanceBelowCooking Top and at Rearof Range Clearances and Dimensions 1 Location Check location where the range will be installed Check for proper electri...

Страница 2: ... safe use of all appliances Never leave the oven door open when the range is unattended lrl _lw IttPIl_ PIIStepping leaning or sitting on the doors ordrawers of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminat...

Страница 3: ...ertified by CSA International Because solid pipe restricts moving the range we recommend using a new flexible conduit 4 to 5 foot length for each new installation and additional reinstallations Always use the 2 new flare union adapters 1 2 NPT x 3 4 or 1 2 I D supplied with the new flexible appliance conduit for connection of the range Normal Installation Steps 1 Anti Tip Bracket Installation Inst...

Страница 4: ...n and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches if regulator has been converted for LP Prop...

Страница 5: ... accurate pressure check have at least two 2 other top burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 _ lVJV J t_ll_ cl Before servicing disconnect electrical...

Страница 6: ... have been carefully checked for leaks and range has been connected to electric power a To check for proper lighting push in and turn a surface burner knob counterclockwise to the LITE position You will hear the igniter sparking b The surface burner should light when gas is available to the top burner Purge air from supply lines by leaving knob in the LITE position until burner ignites Each burner...

Страница 7: ...s been connected to electric power The oven burner is equipped with an electric control system as well as an electric oven burner igniter If your model is equipped with a waist high broil burner it will also have an electric burner igniter These control systems require no adjustment When the oven isset to operate current wiltflow to the igniter It will glow similar to a light bulb When the igniter...

Страница 8: ...er or letter from the serial plate on your range Your serial plate also tells you the rating of the burners the type of fuet and the pressure the range was adjusted for when it left the factory Care Cleaning and Maintenance Refer to the Use Care Manual for cleaning instructions Ifremoving the range is necessaryfor cleaning or maintenance shut off gas supply Disconnect the gas and electrical supply...