background image

GAS WALL OVEN INSTALLATION INSTRUCTIONS

1

INSTALLATION AND SERVICE MUST BE PERFORMED BY

A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

If the information in this manual is not followed exactly, a fire or explosion may result

causing property damage, personal injury or death.

FOR YOUR SAFETY:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other

appliance.

— WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone.  Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service agency or the gas supplier.

NOTE: Wiring diagrams for these appliances are enclosed in this booklet.

P/N 318201550 (0003) Rev. A

English – pages 1-8

Español – páginas 9-17

Wiring Diagram - pages  18-20

Recycled paper

Printed in Canada

Figure 1

Additional Safeguards

• Do not install wall oven beneath the work counter.
• The flue charge shall not be located below the 36" level.

Clearance for complete door opening:

• For model with 2 cavities allow at least 17 5/8".
• For model with 1½ cavity allow at least 19 3/8".

Model with 2 oven cavities

Model with 1½ oven cavity

H

38 

7

/

16

"

37 

3

/

8

"

23 

3

/

8

"

F

G

27"

18"

A

B

C

D

E

Drill a 1½" diameter hole

for gas hook up

Electrical Outlet

Location for model

with 1½ oven

cavity

Electrical Outlet

Location for

model with 2

oven cavities

23 

17

/

32

"

42 

3

/

8

"

21"

19 

3

/

8

"

41 

13

/

16

"

23 

7

/

8

"

25 

3

/

8

"

22 

5

/

16

"

MODEL

CABINET DIMENSIONS

CUTOUT DIMENSIONS

A

B

C

D

E

F

G

H

Model with 2 cavities

19 ½" Min.

2 ½" Min.

24" Min.

16 ¾"

1

/

8

"

22 ½"

24" Min.

42 

1

/

8

"

Model  with 1 ½ cavity

10" Min.

27 ½" Max.

1 ½" Min.

24" Min.

20"

5

/

8

"

22"

23 ½" Min.

37 ½" Min.

39" Max.

Содержание FGB557CESD

Страница 1: ...qualified installer service agency or the gas supplier NOTE Wiring diagrams for these appliances are enclosed in this booklet P N 318201550 0003 Rev A English pages 1 8 Español páginas 9 17 Wiring Diagram pages 18 20 Recycled paper Printed in Canada Figure 1 Additional Safeguards Do not install wall oven beneath the work counter The flue charge shall not be located below the 36 level Clearance for...

Страница 2: ... Refer to figure 1 for the dimensions applicable to your appliance and the space necessary to receive the oven Corners must be square Floor cabinet must be able to support 150 pounds and must be flush with bottom of opening Bricked opening for model with 2 cavities only If oven is to be installed in brick or stone first construct a rectangular wooden frame with sides and top and bottom The inside ...

Страница 3: ...ernal electrical source is used the appliance when installed must be electrically grounded in accordance with local codes or in their absence of local codes with the National Electric Code ANSI NFPA No 70 1987 or latest edition Check all code rules and regulations for connecting the wall oven to be certain the installation conforms with all local municipal and state codes as well as local utility ...

Страница 4: ...th 1 oven cavity only Remove and lay aside the lower vent decorative trim that is taped to the side or to the top of the oven The decorative trim will be fastened to the lower front of the oven after it has been installed in the cabinet There is a 1 height adjustment on models with extension panel see figure 4 With this adjustment and a trim overhang a unit can be installed in existing openings 37...

Страница 5: ... gas to the unit on and off The gas supply line to the unit should be 1 3 cm or 1 9 cm pipe To avoid pilot outage if applicable close all openings in the cabinet cavity that encloses this unit All openings around gas service outlets must be closed at the time of installation Mounting Screws 6 Externally Vented Installations Model With 2 Oven Cavities only IMPORTANT Refer to the serial plate for in...

Страница 6: ... gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 9 LP Propane Gas Conversion A Pressure Regulator Conversion Note Do not remove the Pressure Regulator Convert the Pressure Regulator for use with LP Gas see figure 11 If applicable remove broiler or storage drawer by pulli...

Страница 7: ... tube which sets on the hood of the valve and is locked in place with a Phillips head screw If the air shutter needs adjusting loosen the screw and rotate the shutter to allow more or less air to the burner tube see figure 14 Gasket SMALL End Towards Regulator For Natural Gas ENLARGED End Towards Regulator For L P Gas Figure 11 For Natural Gas the air shutter should be approximately half open For ...

Страница 8: ...a programmable timing operation Model and Serial Number Location The serial plate is located on the left side inner trim of the oven for the model with 1 oven cavity and on the lower oven frame for the model with 2 oven cavities When ordering parts for or making inquires about your wall oven always be sure to include the model and serial numbers and a lot number or letter from the serial plate of ...

Страница 9: ...POR UN INSTALADOR CALIFICADO IMPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR ELÉCTRICO LOCAL LEA Y GUARDE ESTAS INSTRUCCIONES PARA FUTURAS REFERENCIAS Si todas las instrucciones de éste manual no son observadas a la letra se puede ocurrir incendios o explosiones que pueden causar daños materiales lesiones o la muerte PARA SU SEGURIDAD No almacene o utilice gasolina u otros vapores y l...

Страница 10: ...rio en el que poner el horno Las esquinas deben estar cuadradas El piso del gabinete debe soportar una carga de 150 libras y debe estar nivelado con el fondo de la abertura Abertura en ladrillo para modelo con 2 cavidades del mismo tamaño solamente Si el horno va a ser empotrado en ladrillo o piedra construya primero un marco rectangular de madera de en las laterales y arriba y abajo Las dimension...

Страница 11: ... ser conectado a tierra de acuerdo con las normas locales o de acuerdo las National Electrical Code ANSI NFPA No 70 1987 o ultima edición Verifique todos los códigos normas o regulaciones para cerciorarse que la instalación está de acuerdo a los códigos locales estatales y de las empresas de servicio de energía locales El incumplimiento las anteriores recomendaciones puede resultar en un peligroso...

Страница 12: ...a de ventilación que está pegada a la parte exterior del panel del horno La rejilla será fijada a la parte de baja del frente del gabinete después de que éste haya sido instalado en el gabinete Este modelos de horno cuenta con un ajuste de altura de 1 ver figura 4 Con este ajuste y la pestaña de el horno puede ser instalado en aberturas existentes de 37 a 39 de altura Figura 4 Puerta del horno Fon...

Страница 13: ... Esta válvula debe estar localizada en un sitio de fácil acceso para cerrar el suministro de gas a la unidad La línea de suministro de gas por el plancha de cocinar debería tener un tubo de o de Tornillos de montaje 6 Instalaciones ventiladas exteriormente Modelo con 2 Cavidades IMPORTANTE Refersirse a la placa de la serie para información en el tipo de ventilación Si la ventilación está marcada o...

Страница 14: ... topes luego saque hacia afuera Verificar si hay fugas en el electrodoméstico la verificación debe de ser realizada según las instrucciones del fabricante Verifique si hay fugas Luego de conectar la cocina al gas verifique el sistema con un manómetro Si no cuenta con éste instrumento dé la vuelta al suministro de gas de la cocina y utilice un detector de fugas líquidas o agua y jabón en todas las ...

Страница 15: ...regulador esta indicado en la parte superior del pistón Figura 11 Junta PEQUEÑA extremidad hacia el regulador para gas natural GRANDE extremidad hacia el regulador para Gas L P Figura 12 Pasador L P Nat Obturador de aire Junta en forma bellota Junta en forma de bellota del quemador B Ajuste del orificio del quemador del horno vea figura 12 Usando una llave de giro hacia abajo la junta en forma de ...

Страница 16: ...WC 11 Ajuste del la llama del quemador del horno asador Ajuste el obturador de aire Esté localizado en el vénturi jundo a la capucha de la válvula y es fijado en su lugar por un tornillo con cabeza tipo Phillips Si éste necesita ajuste afloje el tornillo y rota el obturador para permitir más o menos aire en el tubo del quemador vea figura 14 Para gas natural la entrada de aire deberá estar aproxim...

Страница 17: ...d de horno y en el armazón de bajo del horno para modelos con 2 cavidades de horno Asegúrese de incluir el modelo número de serie y el número o letra de lote que se encuentran en la placa en todo pedido de partes o solicitud de información acerca de su horno empotrado La placa de número de serie también indica las especificaciones de los quemadores el tipo de combustible y la presión para la cual ...

Страница 18: ...18 WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA For Models with 2 Oven Cavities Para modelo con 2 cavidades ...

Страница 19: ...19 WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA For Self Clean Models with 1 Oven Cavity Para modelos auto limpiables con 1 cavidad ...

Страница 20: ...20 WIRING DIAGRAM DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA For Easy Clean Models with 1 Oven Cavity Para modelos fâcilmente limpiables con 1 cavidad ...

Отзывы: