background image

SERVICE DATA SHEET

241588205

STANDARD - AUTOMATIC DEFROST

TOP MOUNT FREEZER - R134a  

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. 
Untrained persons should not attempt to make repairs due to the possibility of electrical 
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to 
their original position and properly secured.

 

CAUTION

All electrical parts and wiring must be shielded from torch flame. DO NOT allow 
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. 
Excessive heat will distort the plastic liner.

NOTE

Some products come equipped with an Electronic Defrost Control. To initiate defrost, 
depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To 
terminate defrost, depress the fresh food light switch 5 times in 6 seconds. 

PERFORMANCE DATA 

NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING

Capacitor Run or Induction Run

65°F (18°C) Ambient

90°F (32°C) Ambient

Operating Time

25 to 35%

45 to 55%

Freezer Temperature

2° to 8°F (-17° to -13°C)

0° to 5°F  (-18° to -15°C)

Refrigerator Temperature

35° to 40°F (2° to 4°C)

35° to 40°F  (2° to 4°C)

Low Side Pressure (cut-in)  

8 to 16 psig  ( 55 to 110 

kPa)

8 to 16 psig  (55 to 110 kPa)

Low Side Pressure (cut-out)

1 to 4 psig (7 to 28 kPa)

1 to 4 psig (7 to 28 kPa)

High Side Pressure (last 1/3 
cycle)

110 to 120 psig  (758 to 

827 kPa)

150 to 175 psig  (1034 to 1207 

kPa)

Wattage (last 1/3 cycle)

140 to 185

140 to 185

Amps (running)

1.1 to 1.6

1.1 to 1.6

Base Voltage

115 vac (127 vac max)

115 vac (127 vac max)

DEFROST SPECIFICATIONS

Cabinet Size

Thermostat

Heater

Cut-in

Cut-out

Watts

Ohms

18’ & 21’

25°F 

(-4°C)

47°F (8°C)

375

35

14’, 15’ & 17’

25°F (-4°C 47°F (8°C)

325

41

Mechanical Timer - Defrost 30 minutes every 10 hours of compressor run time. 

Electronic Timer (ADC) - Defrost up to 24 minutes every 6-72 hours of compressor run time.

CONDENSER FAN MOTOR

Watts

RPM

Amps

2.3

1100 CW Opposite 

Shaft

0.15 Running

ICE MAKER SPECIFICATIONS

Electrical

115 vac (127 vac max)

60 Hertz

Thermostat

Opens at 48°F (9°C)

Closes at 15°F ( -9°C)

Models with Orange wire close 

at 8.96°F (-12.8°C)

Heater Voltage

165 vac

ICE MAKER CONNECTOR PLUG CONNECTIONS

Wire Number

Wire Color

Connects to:

1

Green / Yellow

Ground

2

Yellow

Water Valve

3

Black 

Line

4

Light Blue

Neutral

IMPORTANT

                                                                                                     
PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

ICE MAKER INFORMATION

Test Cycling: 

Remove cover by inserting screwdriver in notch at  bottom and prying 

cover from housing. Use screwdriver to rotate motor gear counterclockwise until hold-

ing switch circuit is completed. All components of ice maker should function to com-
plete the cycle.  

Water Fill Volume: 

The water fill adjustment screw will change the fill time. One 

full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When 

a water valve is replaced, the fill volume must be checked.   

   

Отзывы: