Содержание FAP094

Страница 1: ...ONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS PORTABL AI R CON DITION ER ELECTRONIC CONTROL P N 220250d396 SZ000373 En YaoKong pl 5 1 2004 11 10 4 54 PM ...

Страница 2: ...er connection to a grounded power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs andlo...

Страница 3: ...occur Common sense and caution must be practiced when installing operating and maintaining any appliance 2 Warranty 3 Product Registration 3 Normal Sounds 4 Important Safety Instructions 4 Energy Saving Ideas 5 Operation of Current Device Description Accessories 6 10 Air Conditioner Features 10 Care and Cleaning 11 Avoid Service Checklist Normal Sounds Sound of Rushinq Air At the front of the unit...

Страница 4: ...nditioner be careful to avoid cuts from sharp metal fins on front and rear coils Do not cover appliance with clothes of any other objects Electrical Information The complete electrical rating of your new room air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards...

Страница 5: ...shed in for correct operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer Unit Description CONTROL PANEL ROOM A_R O_SCHARGE_ REMOTE CONTROL J FRONT ...

Страница 6: ...0 _ _ Fan triode On _ 0_ 0fi 0_ TIMER RUTTONS ON OFF BUTTON POWER INDICATOR Fig 3 REMOTE CONTROL MODE INDICATION MODE SELECTOR FAN SPEED SELECTOR S f Set Temperature F I AAuto 1 Fan _ool High _ ry Med N Heat jLow V Temp A CZD f Node On Off Timer0n _0 FanSpeed T ReselLock O0 tf FAN SELECTION TEMPERATURE CONTROLRUTTONS TimerOff CD_ TIMER BUTTONS ON OFF RUTTON RESET LOCK PIN BUTTONS Fig 4 6 SZ000373 ...

Страница 7: ... Fig 7a b Fig 7a Fig 7b Exhaust Air Oulet Fig 5 WALL DISCHARGE Mount wall adaptor directly over correctly installed duct to outside This usually includes aluminum wall ducting an outside cover See your hardware specialist for correct installation Use wall plugs screws to secure Fig 7c o Attach hose duct to wall adaptor The hose can be extended from its original length of 20 up to 80 but it is best...

Страница 8: ...the selected speed and the display will go dark TIMER OPERATION To start unit at a pre determined time Make sure that the appliance is in the same mode you will need when it turns back on Then turn the unit off Press the Timer On button The display will read 0 00 Pressing the Timer On button will change the time in half hour increments up to 10 hours then full hour increments up to 24 hours The ap...

Страница 9: ...ed and no blockages or kinks can be found then wheel the unit to a drainage point outside and drain as described above Fig 12 Replace the stopper when drained A i _ 0 l_ 0 _s Temp _ 0 _ _i m 0 Dry V o _ 0 _ 0 T m r 0 On Off _ Fig 12 BUCKET FULL INDICATOR REMOTE CONTROL OPERATION _u_ r_ V Temp A FanSpe_d Time_Ol 0 0 J The remote control operates the unit in the same way as the controt panel buttons...

Страница 10: ...see if cieaning is neces sary Trapped parficies in the fiiter can buiid up and cause an accumulafion of frost on the cooling coiis o Puli open the fiiter cover by grasping the handie at the bottom o Remove the fiiter o Wash the fiiter using iiquid dishwashing detergent and warm water Rinse fiiter thoroughiy Gentiy shake excess water from the fiiter Be sure fiiter is thor oughiy dry before replacin...

Страница 11: ...away from coil Reset to a Lower temperature Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Outdoor temperature below 60 F 18 C To defrost the coil set FAN ONLY Mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY Mode Temperature is set too Low for night time coolin...