Specifications
subject to change.
Under-Cabinet Hoods
F30WV16E C / S/ B
30" Wall Mount
Under-Cabinet Hood Specifications
•
Product Shipping Weight (Approx.) – 13 Lbs.
•
Wall-Mount Installation – can be ducted vertically or horizontally.
•
Sones Rating – 6.5
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = TBD
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 2.0 Amps
•
Always consult local and national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
•
Connect vent hood with copper wire only.
•
Minimum installation height allowed from bottom of hood to cooking
surface is 18" - 24".
•
Installation on recessed-bottom cabinets requires attachment of two
wood filler strips at each side of recessed area under cabinet.
•
For outside ventilation.
•
Exhaust Duct Required – 3-1/4" x 10"
(3-1/4" x 10" to 6"-round transition
duct can be used if needed)
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
•
Use metallic flex ducting only to connect rigid duct directly to
transitions
(if allowed by code).
•
Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.
•
Cold weather installations should have additional backdraft damper
installed.
•
Refer to installation instructions on web for detailed duct preparation and
converting exhaust vent blower system for exterior exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Under-Cabinet Vent Hood
F30WV16E
Frigidaire Baseline
Exhaust Options
Vent hood can be vertically or horizontally
ducted outside using rectangular duct.*
For detailed duct preparation and installation
specifications, refer to installation
instructions on web.
*3
1
/
4
" x10"to 6" round duct transition required
for installation of 6"round duct.
Outside Horizontal –
3
1
/
4
" x 10"Rectangular Duct
5
1
/
4
" 5
1
/
4
"
3
7
/
8
"
Cabinet Front
1
/
8
"
7
1
/
2
"
Electrical
access hole
(in wall)
3
/
4
"
Horizontal
duct cutout (in wall)
3
/
8
"
Wood filler strips
30"
13"
max.
cabinet
depth
Minimum 18"-24"
allowed from cooking surface
to bottom of hood
6
"
17
1
/
2
"
Top or rear power
supply locations
3
1
/
4
" x 10" rectangular
duct location (top)
3
1
/
4
" x 10" rectangular
duct location (rear)
30
"
12
"
Cabinet Bottom
5
1
/
4
"
5
1
/
4
"
7
1
/
2
"
Vertical
duct
cutout
9
7
/
8
"
9"
Electrical access hole (in cabinet bottom)
10
5
/
8
"
1
1
/
2
"
6
7
/
8
"
9"
1
1
/
2
"
13
15
/
16
"
13
15
/
16
"
Outside Vertical –
3
1
/
4
" x 10"Rectangular Duct
Wood filler strips (recessed cabinet bottoms only)