Specifications  

subject to change.

Under-Cabinet Hoods

F30WV16E C / S/ B    

30" Wall Mount

Under-Cabinet Hood Specifications

 Product Shipping Weight (Approx.) – 13 Lbs.

• 

Wall-Mount Installation – can be ducted vertically or horizontally.

• 

Sones Rating – 6.5 

• 

Voltage Rating – 120V / 60 Hz / 15 Amps

• 

Connected Load (kW Rating) @ 120 Volts = TBD  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

• 

Amps @ 120 Volts = 2.0 Amps

• 

Always consult local and national electric codes. Check local building 

codes for installation requirements, as they may vary per locale.

• 

Connect vent hood with copper wire only.

• 

Minimum installation height allowed from bottom of hood to cooking 

surface is 18" - 24".

• 

Installation on recessed-bottom cabinets requires attachment of two 

wood filler strips at each side of recessed area under cabinet.

• 

For outside ventilation. 

• 

Exhaust Duct Required – 3-1/4" x 10" 

(3-1/4" x 10" to 6"-round transition 

duct can be used if needed)

 

• 

For most efficient airflow exhaust, use a straight run or as few elbows 

as possible.

• 

Use metallic flex ducting only to connect rigid duct directly to 

transitions

 (if allowed by code).

• 

Thermal breaks such as short section of nonmetallic duct, should be 

used in areas of extreme cold.

• 

Cold weather installations should have additional backdraft damper 

installed.

 Refer to installation instructions on web for detailed duct preparation and 

converting exhaust vent blower system for exterior exhaust ventilation.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Under-Cabinet Vent Hood

F30WV16E

Frigidaire Baseline

Exhaust Options

Vent hood can be vertically or horizontally

ducted outside using rectangular duct.*

For detailed duct preparation and installation

specifications, refer to installation

instructions on web.

*3

1

/

4

" x10"to 6" round duct transition required

for installation of 6"round duct.

Outside Horizontal – 

3

1

/

4

" x 10"Rectangular Duct

5

1

/

4

" 5

1

/

4

"

3

7

/

8

"

Cabinet Front

1

/

8

"

7

1

/

2

"

Electrical

access hole

(in wall)

3

/

4

"

Horizontal

duct cutout (in wall)

3

/

8

"

Wood filler strips

30"

 13"

max.

cabinet

depth

Minimum 18"-24"

allowed from cooking surface

to bottom of hood

6

"

17 

1

/

2

"

Top or rear power

supply locations

1

/

4

" x 10" rectangular

duct location (top)

1

/

4

" x 10" rectangular

duct location (rear)

30

"

12

"

Cabinet Bottom

5

1

/

4

"

5

1

/

4

"

7

1

/

2

"

Vertical

duct

cutout

9

7

/

8

"

9"

Electrical access hole (in cabinet bottom)

10

5

/

8

"

1

1

/

2

"

6

7

/

8

"

9"

1

1

/

2

"

13 

15

/

16

"

13 

15

/

16

"

Outside Vertical – 

3

1

/

4

" x 10"Rectangular Duct

Wood filler strips (recessed cabinet bottoms only)

Содержание F30WV16E C

Страница 1: ... codes for installation requirements as they may vary per locale Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire com Specifications subject to change Available in Features Nominal Width 30 Installation Type Wall Mount Style Under Cabinet Controls Rocker Switch Air Discharge Vertical or Horizontal Air Delivery CFM 160 Blower Type Fan Fan Speeds 2 ...

Страница 2: ...flow exhaust use a straight run or as few elbows as possible Use metallic flex ducting only to connect rigid duct directly to transitions if allowed by code Thermal breaks such as short section of nonmetallic duct should be used in areas of extreme cold Cold weather installations should have additional backdraft damper installed Refer to installation instructions on web for detailed duct preparati...

Страница 3: ...8352 frigidaire ca INSTGDLNS_SSR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front ...

Страница 4: ...5 8352 frigidaire ca INSTGDLNS_TMR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...

Отзывы: