TROUBLESHOOTING
10
1.
Please note, if a power failure occurs due to disconnection of the power
cord, or the power button has been pushed off during an ice making
cycle, small ice chips may formed and lodge in the automatic shovel
causing it to jam. If this occurs, the ice chips may be removed by
disconnecting the power cord and gently pushing the shovel to the rear
of the cabinet and removing the ice chips, then restarting.
2.
Please check if the water reservoir is flat when the ice shovel can not
remove the ice to ice basket. If not, please push the ice shovel gently by
finger, then press POWER button to restart.
PROBLEM
POSSIBLE CAUSE
SUGGESTED SOLUTIONS
The compressor
works
abnormally with
a Buzzing Noise
The voltage is lower
than recommended
Stop the Ice maker and do
not restart until the voltage
is normal.
Water shortage
indicator light is on
There is no water
The pump is full of air
Add to some water until it
reaches MAX position
Press POWER to
button restart
Indicator lights on
display are not on
Blown fuse/No power
Replace fuse / Turn power on
The Ice made is too
large and with
pieces sticking
together.
Ice of previous cycles
left in the water tray
Take out the ice under
the standby state
The ice making
process was
correct, but no ice
came out?
The compressor has
no refrigerant
Compressor damaged
Fan motor damaged
Call the service hotline
CLEANING AND MAINTENANCE
Содержание EFIC206-B-TG-SILVER
Страница 2: ...INTRODUCTION 2 Pour the water into the water tray Ice maker plugged in ...
Страница 15: ......