Section 2 Installation Information
2-2
Pre-Installation Requirements
Tools and materials needed for installation:
• Channel lock adjustable pliers
• Phillips, straight, & square bit screw-drivers
• Adjustable
wrench
• 10 mm socket with ratchet
• Carpenter’s
level
Electrical System Requirements
Circuit - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse
or circuit breaker.
Power Supply - 2 wire, with ground, 120 volt single
phase, 60 Hz, alternating current.
Outlet Receptacle - Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
Grounding Type
Wall Receptacle
Power Cord with
3- Prong Grounded Plug
DO NOT, under any
circumstances, cut,
remove, or bypass the
grounding plug.
Figure 2-1. Electrical Connection
Because of potentially inconsistent voltage capabilities,
the use of this washer with power created by gas
powered generators, solar powered generators, wind
powered generators or any other generator other than
the local utility company is not recommended.
GFI (Ground Fault Interrupter) receptacle is not
required.
NOTE
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as
to whether the appliance is properly grounded.
WARNING
Grounding Requirements
1. The washer MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance
for electrical current.
2. This washer is equipped with a power supply cord
having an equipment-grounding conductor and a
grounding plug, the plug MUST be plugged into an
appropriate, copper wired receptacle that is properly
installed and grounded in accordance with all local
codes and ordinances or in the absence of local
codes, with the National Electrical Codes, ANSI/
NFPA 70 (latest edition). If in doubt, call a licensed
electrician. DO NOT cut off or alter the grounding
prong on the power supply cord. In situations where
a two-slot receptacle is present, it is the owner’s
responsibility to have a licensed electrician replace
it with a properly grounded three prong grounding
type receptacle.