Section 1 Basic Information
1-10
Water Temperature
When AUTO TEMP switch is set to HOT/COLD in the wash
cycle, the hot solenoid is activated and the bleach
solenoid is deactivated for all except the last fi ll in rinse.
For the last rinse fi ll, the wash and bleach solenoids are
activated. When AUTO TEMP switch is set to WARM/
COLD in the wash cycle, the hot and wash solenoids are
activated and the Bleach solenoid is deactivated, for all
except the last fi ll in rinse. For the last rinse fi ll, the
wash and bleach solenoids are activated. When the
AUTO TEMP switch is set to WARM/WARM in the wash
cycle, the hot and wash solenoids are activated and the
Bleach solenoid is deactivated for all except the last fi ll in
rinse. For the last rinse fi ll, the hot and bleach solenoids
are activated. When the AUTO TEMP switch is set to
COLD/COLD, the wash solenoid is activated and the hot
solenoid cycles to warm the water to 65°. For the last
rinse fi ll, the wash and bleach solenoids are activated.
When the TEMP switch is set to COLD/COLD in the wash
cycle, the wash solenoid is activated and the bleach
solenoid is deactivated for all except the last fi ll in rinse.
For the last rinse fi ll, the wash and bleach solenoids are
activated.
Auto Temp System
The auto temp system controls the minimum temperature
of the cold water setting (approximately 65°F.) and the
temperature of the warm and hot water setting
(approximately 90°F and 120°F). On select models
with a sanitary wash cycle, when the control is set to
sanitary wash, the water temperature is raised to 152°F
in the wash cycle. The auto temp system is made up of
the control board and a positive thermal sensor mounted
in the water inlet valve assembly. On select models, a
positive thermal sensor (drum sensor), a heater control
board, and a 1000 watt heating element located in the
bottom rear of the drum are added to auto temp system.
If the hot water supply in the house is below the auto
temp setting, the drum heater heats the water in the
wash cycle. (See Figure 1-20)
When a warm or hot temperature is selected in the wash
cycle, the control board connects the hot water solenoid
to neutral and cycles the center cold water solenoid off
and on to regulate the temperature. When a cold
temperature is selected, the control board connects the
center cold water solenoid to neutral and cycles the hot
water solenoid off and on to regulate the temperature.
When a warm rinse is selected for the fi nal rinse, the
control connects the outside cold solenoid to neutral
and cycles the hot solenoid.
Figure 1-17. Auto Temp Sensor Location
Figure 1-18. Positive Thermal Sensor
Figure 1-19.
Figure 1-20.
+T NTC
J11
C6.1
C6.2
C6.3
C6.4
C6.5
AQUA
YEL
PURP
TAN
GRAY
DRUM WATER
HEATER
WHT/RED
BLK/WHT
J3
C3.3
C3.3
C3.2
C3.1
C3.1
J2
J1 C2.2
C2.1
HEATER CONTROL BOARD
N L1
Auto Temp
Sensor
Heater
Control
Board
Содержание Affinity 6000 Series
Страница 2: ......