5.4   Install The Panel

6.    CONNECT THE DRAIN PIPE

CAUTION

CAUTION

CAUTION

NOTE

CAUTION

Never put the panel face down on floor or against the 

wall, or on bulgy objects.

Never crash or strike it.

Don’t use forcing strength to crack the water-pumping pipe. 

The joints in drain system must be sealed to avoid water leakage.

All the pictures in this manual are for explanation 

purpose only. They may be slightly different from the 

air conditioner you purchased(depend on model). The 

actual shape shall prevail.

Do not coil the wiring of the swing motor into the seal 

sponge.

1    Remove the air-in grill.

2    Remove the installation covers at the four corners

3    Install the panel

4   Hang the air-in grill to the panel, then connect the lead 

terminator of the swing motor and that of the control box with 

corresponding terminators on the body respectively.

5   Relocate the air-in grill in the procedure of reversed order.

6   Relocate the installation cover.

Slide two grill switches toward the middle at the same time, 

and then pull them up. 

(Refer to fig.5-9)

Draw the grill up to an angle of about 45°, and remove it. 

(Refer 

to fig.5-10)

 

6.1 Install the drain pipe of indoor unit

1) The drainpipe can use PVC pipe (external diameter about 

37~39mm, inner diameter is 32mm). 

2) Joint drainpipe connector to the end side of water pumping pipe, 

and fix drainpipe together with water outflow pipe and thermal 

insulation tube by clasp of water outflow pipe (attached).  

3) Water-pumping pipe and drainpipe from main body must be 

wrapped by insulation tube evenly, and bound by tighten band for 

obstructing air getting in and coagulation.

4) Prevent from water backflow into unit inside during shutdown, the 

drain pipe shall place down side and drain water to outdoor (drain 

side), the gradient of the drain pipe should be higher than (1/100), 

without salient and water remain.

(Refer to Fig.6-1 a)

5) When connecting drainpipe, don’t drag the pipe that would pull 

the main unit. For this, please arrange bearing points every 0.8 to 1.0 

meter to avoid pipe be bended 

(See Fig.6-1 b).

6) When connect a lengthen drainpipe, apply protective tube to wrap 

its indoor parts for ensuring the lengthen part connected tightly.   

7) In case the drainpipe outlet is higher than pumping connective 

pipe of the main body, the drainpipe must be arranged upwards 

vertically by using connective assembly of the water outlet for 

vertical bending, and the height of the drainpipe shall set to the 

defrosting pan surface no more than 1000mm (four-way cassette) or 

600mm (slim four-way cassette), otherwise, too much backflow while 

shutdown would leads to overflow (Refer to Fig.6-2).

8) Base on the actual requirement to bend piping, and use 

connective assembly of water outlet in terminal box for pipe layout.

9) The height from floor to the end of drainpipe or the bottom of drain 

slot must more than 50 mm. Don’t immerse the end of drainpipe or 

the bottom of drain slot into water. When drain condensate liquid to 

raceway, please bend the drainpipe to a U-sharped hydroseal for 

avoiding stench transmitted by drainpipe to indoor.       

Wrench off the bolts, loose the rope of the installation covers, 

and remove them.

 (Refer to fig.5-11)

Align the swing motor on the panel to the tubing joints of the 

body properly. 
Fix hooks of the panel at swing motor and its opposite sides 

to the hooks of corresponding water receiver. Then hang the 

other two panel hooks onto corresponding hangers of the 

body.

Adjust the four panel hook screws to keep the panel 

horizontal, and screw them up to the ceiling evenly. 
Regulate the panel in the direction of the arrow  slightly to fit 

the panel's center to the center of the ceiling's opening. 

Guarantee that hooks of four corners are fixed well.

Keep fastening the screws under the panel hooks, until the 

thickness of the sponge between the body and the panel's 

outlet has been reduced to about 4~6mm. The edge of the 

panel should contact with the ceiling well.    

Fasten the rope of installation cover on the bolt of the 

installation cover. 
Press the installation cover into the panel slightly. 

If the gap between the panel and ceiling still exists after 

fastening the screws, the height of the indoor unit should be 

modified again. 
You can modify the height of the indoor unit through the 

openings on the panel's four corners, if the lift of the indoor 

unit and the drainpipe is not influenced.

Содержание KFC-CI-2T-300D1

Страница 1: ...ng your air conditioner please read this manual carefully and keep it for future reference INSTALLATION OWNER S MANUAL Fancoil Four way Cassette Type MKD V300 V1 KFC CI 2T 300D1 MKD V500 V1 KFC CI 2T...

Страница 2: ......

Страница 3: ...the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be installed in the laundry Before obtaining access to terminals all s...

Страница 4: ...install the air conditioner in the following locations There is petrolatum existing There is salty air surrounding near the coast There is caustic gas the sulfide for example existing in the air near...

Страница 5: ...hook 4 4 2 Installation hook 4 4 3 Installation paper board 1 1 4 Bolt M6 4 Tubing Fittings 5 Soundproof insulation sheath 2 2 Drainpipe Fittings 6 Out let pipe pipe 1 1 7 Out let pipe sheath 1 8 Out...

Страница 6: ...Install the main body Face the concave side of the installation hooks toward the expansible hooks Determine the length of the installation hooks from the height of ceiling then cut off the unnecessary...

Страница 7: ...ner insulation Insulation local Central hole Grid switch All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend o...

Страница 8: ...pipe joint Connecting point of drain pipe Ground Ground Panel Panel Outlet Outlet 600mm ceiling hole 600mm ceiling hole Outlet Outlet Inlet Inlet Unit mm Tubing side FIGURES 3 Fig 5 12 Fig 5 13 Fig 5...

Страница 9: ...then drainpipe apply protective tube to wrap its indoor parts for ensuring the lengthen part connected tightly 7 In case the drainpipe outlet is higher than pumping connective pipe of the main body th...

Страница 10: ...1 0m Lean over 1 100 Lean over 1 100 Pump pipe clasp the fittings Pump pipe clasp the fittings Max 1000mm Max 600mm Fig 6 1 Fig 6 2 0 8 1 0 m 1 0 m a b 5 Turn off the power drain the water away The d...

Страница 11: ...ther the switch on the remote controller works well b Whether the buttons on the remote controller works well c Whether the air flow louver moves normally d Whether the room temperature is adjusted we...

Страница 12: ...mild detergent to clean it and dry out in cool place Caution Do not dry out the air filter under direct sunshine or with fire The air in side should face up when using vacuum cleaner See fig 9 3 The...

Страница 13: ...ies of remote controller exhausted or other problem of controller Wait for the comeback of power Switch on the power Replace the fuse Replace the batteries or check the controller Air flowing normally...

Страница 14: ...cated on the display is FAN ONLY The temperature cannot be set during FAN mode The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when...

Страница 15: ...lamp defrosting lamp alarm lamp 1 Room temperature sensor checking channel is abnor mal X X X 2 Evaporator sensor checking channel is abnormal X X X 3 EEPROM malfunction X X 4 Water level switch malf...

Страница 16: ......

Отзывы: