Frigicoll KFC-CI-2T-300D1 Скачать руководство пользователя страница 11

Installation & Owner’s Manual

9

 

N
L

N
L

4

3

2

1

N
L

3
2

1

Table 7-1

AIR FLOW(m

3

/h)

510~2550

POWER

PHASE

1-phase

FREQUENCY AND VOLT

220-240V~ 50Hz

CIRCUIT BREAKER/FUSE(A)

15/15

INDOOR UNIT POWER 

WIRING(mm

2

)

BELOW 20M

Twisted pairwire 2.5mm

2

BELOW 50M

Twisted pairwire 6mm

2

GROUND WIRING(mm

2

)

2.5

The power cord type designation is H05RN-F or above.

1. 

 The test operation must be carried out after the entire 

installation has been completed.

2. 

Please confirm the following points before the test operation:

3. 

 According to the user's requirement, install the remote 

controller frame where the remote controller's signal can reach 

the indoor unit smoothly.

4. 

Test operation

The indoor unit and outdoor unit are installed properly.
Tubing and wiring are correctly completed.
The water pipe system is leakage-checked.the drainage is 

unimpeded.
The heating insulation works well.
The ground wiring is connected correctly.
The length of the tubing  has been recorded.
The power voltage fits the rated voltage of the air 

conditioner.
There is no obstacle at the outlet and inlet of the outdoor 

and indoor units.
The air conditioner is pre-heated by turning on the power.

Set the air conditioner under the mode of "COOLING" with 

the remote controller, and check the following points. If there 

is any malfunction, please resolve it according to the chapter 

"Troubleshooting" in this manual. 

a. Whether the switch on the remote controller works well.

b. Whether the buttons on the remote controller works well.

c. Whether the air flow louver moves normally.

d. Whether the room temperature is adjusted well.

e. Whether the indicator lights normally.

f. Whether the temporary buttons works well.

g. Whether the drainage is normal.

h. Whether there is vibration or abnormal noise during 

operation.

I.  Whether the air conditioner heats well in the case of the 

HEATING/COOLING type.

In the event, client applies for the Remote Control Function:

Firstly, dial code SW3 must switch off.

Secondly, connect the signal wires to CN17.

Finally, the defrost indicator in LCD flashing in 5Hz at the 

time remote controlling indoor unit’s switch be dialed to OFF.

A protection feature prevents the air conditioner from being 

activated for approximately 3 minutes when it is restarted 

immediately after shut off.

If the supply cord is damaged, it must be replaced by the 

manufacturer or its service agent or a similarly qualified person in 

order to avoid a hazard.

Plan eof Indoor Unit

Signal Reciver

5-core Connecting Group

5-core Shield Cable 5X0.5mm

2

Wire Controller

VA

LV

E

VAL

VE-C

VAL

VE-H

Power:220-240v~ 50Hz 3 core 3X2.5mm

2

Electric Conrolling Box’

s Plug Cn 10

Indoor Unit Electric  Conrolling Box

Main Board

Power:220-240v~ 50Hz 3 core 3X2.5mm

2

Power:220-240v~ 50Hz 3 core 3X2.5mm

2

Four-way Cassette

Two-Pipe(compact)

Four-way Cassette

Four-Pipe(compact)

Four-way Cassette

10-core Connecting  Wire Group

7.2   Wiring figure

NOTE

8.  TEST OPERATION

CAUTION

AIR CONDITIONE 

AND WIRE CONTROLER WIRING

Содержание KFC-CI-2T-300D1

Страница 1: ...ng your air conditioner please read this manual carefully and keep it for future reference INSTALLATION OWNER S MANUAL Fancoil Four way Cassette Type MKD V300 V1 KFC CI 2T 300D1 MKD V500 V1 KFC CI 2T...

Страница 2: ......

Страница 3: ...the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not be installed in the laundry Before obtaining access to terminals all s...

Страница 4: ...install the air conditioner in the following locations There is petrolatum existing There is salty air surrounding near the coast There is caustic gas the sulfide for example existing in the air near...

Страница 5: ...hook 4 4 2 Installation hook 4 4 3 Installation paper board 1 1 4 Bolt M6 4 Tubing Fittings 5 Soundproof insulation sheath 2 2 Drainpipe Fittings 6 Out let pipe pipe 1 1 7 Out let pipe sheath 1 8 Out...

Страница 6: ...Install the main body Face the concave side of the installation hooks toward the expansible hooks Determine the length of the installation hooks from the height of ceiling then cut off the unnecessary...

Страница 7: ...ner insulation Insulation local Central hole Grid switch All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend o...

Страница 8: ...pipe joint Connecting point of drain pipe Ground Ground Panel Panel Outlet Outlet 600mm ceiling hole 600mm ceiling hole Outlet Outlet Inlet Inlet Unit mm Tubing side FIGURES 3 Fig 5 12 Fig 5 13 Fig 5...

Страница 9: ...then drainpipe apply protective tube to wrap its indoor parts for ensuring the lengthen part connected tightly 7 In case the drainpipe outlet is higher than pumping connective pipe of the main body th...

Страница 10: ...1 0m Lean over 1 100 Lean over 1 100 Pump pipe clasp the fittings Pump pipe clasp the fittings Max 1000mm Max 600mm Fig 6 1 Fig 6 2 0 8 1 0 m 1 0 m a b 5 Turn off the power drain the water away The d...

Страница 11: ...ther the switch on the remote controller works well b Whether the buttons on the remote controller works well c Whether the air flow louver moves normally d Whether the room temperature is adjusted we...

Страница 12: ...mild detergent to clean it and dry out in cool place Caution Do not dry out the air filter under direct sunshine or with fire The air in side should face up when using vacuum cleaner See fig 9 3 The...

Страница 13: ...ies of remote controller exhausted or other problem of controller Wait for the comeback of power Switch on the power Replace the fuse Replace the batteries or check the controller Air flowing normally...

Страница 14: ...cated on the display is FAN ONLY The temperature cannot be set during FAN mode The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when...

Страница 15: ...lamp defrosting lamp alarm lamp 1 Room temperature sensor checking channel is abnor mal X X X 2 Evaporator sensor checking channel is abnormal X X X 3 EEPROM malfunction X X 4 Water level switch malf...

Страница 16: ......

Отзывы: