background image

PULSE915-LRW_User_Manual

FCC Statement

1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.

To comply with RF exposure requirements, a minimum separation distance of

 

2

0

cm

 must be maintained between the user’s body and the 

device

, including the antenna. 

 

2.

 

Changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

party

 

responsible

 

for

 

compliance

 

could

 

void

 

the

 

user's

 

authority

 

to

 

operate

 

the

 

equipment.

NOTE:
This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

This

 

equipment

 

generates

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

 

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.
Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

Friendcom

 

has

 

always

 

been

 

committed

 

to

 

technological

 

innovation.

 

Our

 

aim

 

is

 

to

 

provide

 

customers

 

with

 

timely

 

and

 

comprehensive

 

service.

 

For

 

any

 

assistance,

 

please

 

contact

 

our

 

Shenzhen

 

headquarters:

FRIENDCOM

 

TECHNOLOGY

 

CO.,

 

LTD.

7th

 

Floor,

 

17

 

Building,

 

Guangqian

 

Industrial

 

Park,

 

Xili

 

Town,

 

Nanshan

 

District,

 

Shenzhen,

 

518055,

 

China

Tel:

 

+86-755-86026600

 

+86-755-

 

23230320

Fax:

 

+86-755-86026300

For

 

technical

 

support,

 

or

 

to

 

report

 

documentation

 

errors,

 

please

 

visit:

http://www.friendcom.com

Or

 

email

 

to:

 

[email protected]

Page

 

1

 

/

 

23

Содержание PULSE915-LRW

Страница 1: ...PULSE915 LRW Terminal User Manual LoRaWAN Terminal Series Version 2 1 Date 2020 09 11 www friendcom com...

Страница 2: ...th the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harm...

Страница 3: ...s described herein may include or describe copyrighted Friendcom material and are considered technical proprietary of Friendcom CO LTD Accordingly any copyrighted material of Friendcom and its licenso...

Страница 4: ...tion_User_Manual Conventions Symbol Indication This warning symbol means danger You are in a situation that could cause fatal device damage or even bodily damage Means reader be careful In this situat...

Страница 5: ...all sensor type Update the format of proactive data reporting Added data short frame format Update magnet active time and corresponding functions 1 2 2020 04 Update product description Added firmware...

Страница 6: ...0 3 1 Wiring definition 10 3 2 Pulse Acquisition 11 3 2 1 Active Pulse 12 3 2 2 Passive Pulse 12 4 Data Format And Setting Command 12 4 1 Data Format Of Reporting 12 4 2 Setting Command 14 5 Parameter...

Страница 7: ...Table Index Table 2 1 Specifications of PULSE915 LRW 9 Table 3 1 Wiring definition of PULSE915 LRW 11 Table 3 2 Active pulse wiring 12 Table 3 3 Passive Pulse wiring 12 Table 4 1 Format of commands 14...

Страница 8: ...SE915 LRW_User_Manual Page 7 23 Figure Index Figure 3 1 PCB wiring diagram 11 Figure 5 1 Magnet activation position 19 Figure 6 1 Dimensions of PULSE915 LRW 21 Figure 6 2 Installation of PULSE915 LRW...

Страница 9: ...t active data reporting PULSE915 LRW supports two kinds of pulse signal output sensors of Hall and reed switch That enables it to operate with any pulse emitting device water gas electricity etc With...

Страница 10: ...humidity 5 RH to 95 RH Power supply Pre installed long life battery 2 6V to 3 7V Power consumption 8 A Standby mode Radio characteristics Tx Power Max 20dBm Rx Sensitivity 138dBm Communication range U...

Страница 11: ...ull attention must be given to driving at all times in order to reduce the risk of an accident Using the terminal while driving causes distraction and can lead to an accident Please comply with laws a...

Страница 12: ...A Blue Single pulse sampling using this port 4 PUL B Pulse sampling port B Purple 5 IO1 R Serial port reception Green 6 IO1 T Serial port transmission Yellow 7 GND Ground Brown 8 LINE Wire break dete...

Страница 13: ...he ports that need to be used for passive pulses are as follows Table 3 3 Passive Pulse wiring Port Single pulse Double pulse GND PUL A PUL B 4 Data Format And Setting Command 4 1 Data Format Of Repor...

Страница 14: ...r to the check Long data frame format Name Byte Note Frame header 1 Fixed 0x55 Frame number 1 Data frame accumulator value range 0 to 255 cyclic accumulation Address field 4 The device address the fac...

Страница 15: ...868 cubic meters 00 39 50 00 It is the value of freezing in previous day representing 395000 liters converted to 395 cubic meters 19 12 13 16 31 09 It is the current time of the equipment when transm...

Страница 16: ...example to set the pulse constant is 1000 the command is as follows AT P 1000 Set PulseConst 1000 Error AT T RTC real time clock query RTC real time year month day_week_hour minute second Error AT T x...

Страница 17: ...l 2 is double Pulses 1 AT NP Number of pulses Set type for single or double pulse valid digits 1 2 Example AT NP 1 Set Pulses 1 AT RC Read reporting period Report Cycle AT RC Report cycle Set the repo...

Страница 18: ...nsmit power to 20dBm the command is AT POWER 20 POWER 20 AT ID DevAddr xxxxxxxx Set DevAddr xxxxxxxx to an 8 digit hexadecimal number For example set the DevAddr ID to 01234567 the command is AT ID De...

Страница 19: ...ulse type single or double pulse sensor type hall or reed switch and other LoRaWAN information The configuration mode supports wired and wireless For detailed operation steps users can refer to Friend...

Страница 20: ...ommand must be sent within 30 seconds If the product does not detect the configuration command in 30 seconds the configuration mode will be exited Once the command is received the product will keep in...

Страница 21: ...and whether the current mode is OTAA it will automatically join the network if both are satisfied The network access result can be verified by triggering whether the data report is successful The para...

Страница 22: ...PULSE915 LRW_User_Manual Page 21 23 Figure 6 1 Dimensions of PULSE915 LRW...

Страница 23: ...1 Ties installed in water pipes 2 Use screw to fixed it through side fixing holes 3 Mounted on DIN35 rails 4 Use screw to fixed it through front fixing holes 6 3 Transportantion and Storage Storage 5...

Отзывы: