PULSE915-LRW_User_Manual
Page
16
/
23
hexadecimal digits.
Example: AT+DA
=ABCDEF01
AT+VP
Read pull-up resistor
configuration of external
Vcc and two pulse
sampling ports
Vcc = **(ON), Pull Up =
**(OFF)
AT+VP=”vcc
state”,”Pull up state”
Set pull-up resistor of
external Vcc and two
pulse sampling ports.
ON is open
OFF is close
Example: AT+VP=ON,
OFF
Set Vcc = ON, Pull Up =
OFF
AT+NP
Read pulse type,
support signal and
double type.
1 is signal
2 is double
Pulses = 1
AT+NP=“Number of
pulses”
Set type for single or
double pulse, valid
digits: 1, 2
Example: AT+NP=1
Set Pulses = 1
AT+RC
Read reporting period
Report Cycle = ****
AT+RC=“Report cycle”
Set the reporting period
in minutes.
Valid range: 1-99999
Example: AT+RC=1440
Set Report Cycle = ****
AT+UFM
Query report frame
format
Frame Mode = 1
AT+UFM=“Update
frame mode”
Configure the report
frame format, which can
be set to two formats:
short frame and long
frame.
0 short frame format
1 long frame format
Example: AT+UFM=1
Set Frame Mode = 1
AT+RST
Reset the device
Reset now
AT+V
Query the current
software version
version:0.3
Error