background image

1998

TwinTemp

®

 J

Series

AMERICA’S BEST AIR CONDITIONER

YS09J10
YS13J33
YM18J34A
YL24J35A
ES12J33
ES15J33A
EM18J34A
EL24J35A
EL33J35
EK12J33A
EK18J34A

Service & Parts

Manual

Содержание YL24J35A

Страница 1: ...1998 TwinTemp J Series AMERICA S BEST AIR CONDITIONER YS09J10 YS13J33 YM18J34A YL24J35A ES12J33 ES15J33A EM18J34A EL24J35A EL33J35 EK12J33A EK18J34A Service Parts Manual...

Страница 2: ...odels 13 REFRIGERANT REVERSE CYCLE Refrigerant Flow Chart Cooling Cycle 14 Refrigerant Flow Chart Heating Cycle 14 INSTALLATION INSTRUCTIONS Installation Instructions for DC 2 Drain Kit 15 COMPONENTS...

Страница 3: ...hart 26 Troubleshooting Cooling 27 Troubleshooting Heating Heat Pump Models 31 Troubleshooting Heating Cooling Electric Models 34 WIRING DIAGRAMS YS09J10 618 200 04 36 YS13J33 618 200 02 37 YM18J34A 6...

Страница 4: ...QStar S Small Chassis M Medium Chassis L Large Chassis W Built In H Hazardgard 3rd 4th DIGITS APPROXIMATE BTU HR Cooling Heating BTU HR capacity listed in Specifications Performance Data Section 5th D...

Страница 5: ...nditions of inside temperature and humidity The load calculation form is based on outside design temperature of 95 FDB and 75 FWB It can be used for areas in the Continental United States having other...

Страница 6: ...es or less in thickness is considered Light Construction An insulated wall or masonry wall over 8 inches in thickness is considered Heavy Construc tion 3b Multiply the total length linear feet of all...

Страница 7: ...TTJ 0198 10 97 Page 7 of 64 COOLING LOAD ESTIMATE FORM...

Страница 8: ...ill deliver at indicated ambient temperature Below is an example using the heat load form A space to be conditioned is part of a house geographi cally located in an area where the lowest outdoor ambi...

Страница 9: ...TTJ 0198 10 97 Page 9 of 64...

Страница 10: ...oling 780 1325 1860 2665 1325 1860 2645 Hertz 60 60 60 60 Fuse Breaker Size 15 20 30 30 Amps 16 0 19 5 24 0 14 7 17 0 22 4 Watts 3500 4200 5500 2900 3500 4650 BTUH 10700 13000 17300 8900 10600 14300 F...

Страница 11: ...dity PERFORMANCE DATA YS09J10 YS13J33 YM18J34A YL24J35A Heating AHAM 70 F Inside 47 F Outside 8300 12400 12300 17200 17200 23000 22800 70 F Inside 35 F Outside 10700 8900 13000 10600 17300 14300 Evapo...

Страница 12: ...4 22 4 14 7 17 0 Total Watts Cooling 1140 1665 1850 2610 3670 1250 1875 1090 1655 1830 2640 3610 1250 1875 Hertz 60 60 60 60 60 60 60 Fuse Breaker Size 20 20 30 30 30 20 30 Fan RPM 1120 1100 1120 110...

Страница 13: ...53 0 32 0 13 3 EL33J35 52 0 28 0 71 0 299 17 0 94 0 81 0 35 0 18 0 EK12J33A 57 0 23 0 79 0 293 5 8 26 3 26 0 11 8 6 2 EK18J33A 55 0 25 0 73 0 262 8 2 42 0 46 0 30 0 8 8 Rating Conditions 80 F Room Ai...

Страница 14: ...TTJ 0198 10 97 Page 14 of 64...

Страница 15: ...24 x 3 8 long machine screws and 10 24 hex nuts provided STEP 3 SQ KQ YQ Models Drill two holes in outer shell as shown in Figure 3 Also drill a 3 8 diameter hole in the base pan 3 from the back and 3...

Страница 16: ...compressor body clean point of contact as a good connection is a must and the other probe in turn to each compressor terminal see Figure 2 If a reading is obtained the compressor is grounded and must...

Страница 17: ...w The overload is connected in series with the common motor terminal Should the internal temperature and or current draw be come excessive the contacts in the overload will open turning off the compre...

Страница 18: ...a deflection on the pointer then gradually move back to infinity 4 Reverse the leads of the probe and momentarily touch the capacitor terminals The deflection of the pointer should be two times that...

Страница 19: ...ol Position between terminals C and 3 C2 and 2 LO and M S AR and 5 3 Med Cool Position between terminals C and 3 C2 and 2 M and M S AR and 5 4 Hi Cool Position between terminals C and 3 C2 and 2 H and...

Страница 20: ...MOSTAT ADJUSTMENT No attempt should be made to adjust thermostat Due to the sensitivity of the internal mechanism and the so phisticated equipment required to check the calibration it is suggested tha...

Страница 21: ...on the heating element and turn off the compressor The room thermostat will then control the cycling of the element when the selected indoor temperature is reached Testing of the elements can be made...

Страница 22: ...densate which collects in the drain pan is picked up by the condenser fan blade and sprayed onto the condenser coil This assists in cooling the refrigerant plus evaporating the water During the heatin...

Страница 23: ...he direction of the open pilot tube port which provides a path to the center tube Pressure which will increase in the opposite end of the valve will escape through a bleed port located in each piston...

Страница 24: ...ation circuit or repairing refrigerant leaks Compressor condenser evaporator capillary tube refrigerant leaks etc 1 Recover the refrigerant from the system at the process tube located on the high side...

Страница 25: ...lined under her metic component replacement ROTARY COMPRESSOR SPECIAL TROUBLESHOOTING AND SERVICE Basically troubleshooting and servicing rotary compres sors is the same as on the reciprocating compre...

Страница 26: ...TTJ 0198 10 97 Page 26 of 64...

Страница 27: ...TTJ 0198 10 97 Page 27 of 64...

Страница 28: ...TTJ 0198 10 97 Page 28 of 64...

Страница 29: ...TTJ 0198 10 97 Page 29 of 64...

Страница 30: ...TTJ 0198 10 97 Page 30 of 64...

Страница 31: ...O CORRECT Check continuity of switch Incorrect wiring Inoperative system switch Check applicable wiring diagram PROBLEM POSSIBLE CAUSE TO CORRECT Defective thermostat Heat anticipator resistor shorted...

Страница 32: ...at adequately Outdoor thermostat does not cut off compressor at the preselected tem perature and bring on heating element Fresh air or exhaust door open Dirty filter Unit undersized Defective thermost...

Страница 33: ...outer coil Replace heating capillary tube Switch unit several times from heating to cooling Check temperature rise across coil Refer to specification sheet for correct tempera ture rise De energise so...

Страница 34: ...ghten all terminals PROBLEM POSSIBLE CAUSE TO CORRECT Restricted filter Cycling high limit control Exhaust or fresh air door open Heating inadequate Clean as recommended in Owner s Manual Control is s...

Страница 35: ...pletely bypassing hot gas Cooling adequate heating insufficient Check for partially starved outer coil Replace heating capillary tube Switch unit several times from heating to cooling Check temperatur...

Страница 36: ...TTJ 0198 10 97 Page 36 of 64...

Страница 37: ...TTJ 0198 10 97 Page 37 of 64 WIRING DIAGRAM FOR MODELSYS13J33 YM18J34A YL24J35A...

Страница 38: ...TTJ 0198 10 97 Page 38 of 64 WIRING DIAGRAM FOR MODELS ES12J33 ES15J33A EM18J34A EL24J35 EL33J35 EK12J33A EK18J34A...

Страница 39: ...TTJ 0198 10 97 Page 39 of 64...

Страница 40: ...TTJ 0198 10 97 Page 40 of 64...

Страница 41: ...ctric Supply 30 Amp 250 Volt 1 4 606 072 04 Switch System 8 Position 1 1 1 1 5 618 061 00 Switch Rocker Yes No 1 1 1 1 6 618 224 00 Thermostat Cool Heat 1 1 1 1 613 503 13 Thermostat Defrost 1 1 1 1 7...

Страница 42: ...555 Capillary Tube Cooling 042 I D x 40 42 Long 1 03760473 Capillary Tube Heating Cooling 059 I D x 27 30 Long 1 03760518 Capillary Tube Cooling 054 I D x 273 8 30 Long 1 01389985 Capillary Tube Heati...

Страница 43: ...230 00 Holder Filter 2 2 2 2 24 618 202 00 Airfoil 1 1 1 24 618 202 01 Airfoil 1 618 206 00 Bracket Resistor Block 1 1 1 1 915 003 02 Clamp Supply Cord 25 605 420 03 Fan Blade 1 1 25 605 420 04 Fan B...

Страница 44: ...t Compressor 3 3 3 36 01150934 Grommet Compressor 3 37 914 004 00 Screw Compressor Mounting 3 3 3 3 38 618 102 00 Plenum Assembly 1 1 1 38 618 105 00 Plenum Assembly 1 618 093 00 Knob Fresh Air Exhaus...

Страница 45: ...46 606 103 03 Gasket Vinyl 1 1 1 1 617 173 01 Gasket Foam 1 1 1 1 608 460 16 Bag Assembly Hardware 1 1 1 1 618 116 03 Carton Shipping 1 1 618 116 04 Carton Shipping 1 618 116 05 Carton Shipping 1 618...

Страница 46: ...TTJ 0198 10 97 Page 46 of 64...

Страница 47: ...TTJ 0198 10 97 Page 47 of 64...

Страница 48: ...610 803 37 Capacitor 25 7 5 MFD 370 V 1 1 7 610 803 36 Capacitor 30 7 5 MFD 370 V 1 618 208 00 Wire Harness Fan Motor 1 1 1 618 213 00 Wire Harness Compressor 1 618 214 00 Wire Harness Compressor 1 6...

Страница 49: ...1 1 1 618 076 00 Grommet Suction Line 1 1 1 618 148 00 Connector Fresh Air Exhaust 1 1 1 21 618 172 00 Cover Top 1 1 1 22 618 167 00 Insulation Top Cover 1 1 1 618 168 00 Insulation Left Side Deck 1...

Страница 50: ...ith Handle 2 2 2 39 618 257 00 Outer Shell Carton with Sill Plate 1 1 39 618 257 01 Outer Shell Carton with Sill Plate 1 40 618 084 01 Sill Plate 1 1 1 618 196 00 Guide Shell 2 2 2 41 618 089 00 Grill...

Страница 51: ...EM SERIES PARTS LIST REF PART NO DESCRIPTION APPLICATION E E E S S M 1 1 1 2 5 8 J J J 3 3 3 3 3 4 A A OPTIONAL ACCESSORIES 01900 235 Drain Condensate Connection Kit DC 2 x x x 610 089 03 Start Kit C...

Страница 52: ...TTJ 0198 10 97 Page 52 of 64...

Страница 53: ...TTJ 0198 10 97 Page 53 of 64...

Страница 54: ...00 Wire Harness Compressor 1 615 963 01 Fuse Link 1 1 618 279 00 Heater Limit 1 1 REFRIGERATION SYSTEM COMPONENTS 10 618 500 03 Coil Evaporator 1 10 618 500 04 Coil Evaporator 1 11 618 502 09 Coil Co...

Страница 55: ...181 00 Scroll 1 1 34 618 215 00 Door Slide Assembly 1 1 35 618 095 01 Base Pan 1 1 618 074 00 Drain Pan 1 1 601 799 00 Bellows Drain Valve 1 1 618 188 02 Grille Assembly Rear 1 1 36 01150934 Grommet...

Страница 56: ...618 116 05 Carton Shipping 1 1 618 140 00 Pad Shipping Bottom 1 1 618 141 00 Pad Shipping Top 1 1 618 118 02 Tube Shipping Front Rear 2 2 618 196 00 Guide Shell 2 2 47 600 733 00 Gasket Window Foam 1...

Страница 57: ...TTJ 0198 10 97 Page 57 of 64...

Страница 58: ...TTJ 0198 10 97 Page 58 of 64...

Страница 59: ...18 213 00 Wire Harness Compressor 1 618 213 02 Wire Harness Compressor 1 8 618 080 01 Resistor Block 230 Volt 1 1 9 618 786 00 Heater Element 3 3 KW 1 9 618 786 01 Heater Element 4 0 KW 1 615 963 01 F...

Страница 60: ...608 658 09 Filter Air 1 618 230 00 Holder Filter 2 2 24 618 202 00 Airfoil 1 1 618 168 00 Insulation Left Side Deck 1 1 915 003 02 Clamp Supply Cord 1 1 25 605 420 03 Fan Blade 1 25 605 420 04 Fan Bla...

Страница 61: ...00 Grille Intake 1 618 199 00 Latch Intake Grille 2 2 42 602 944 08 Wingboard 1 42 602 944 09 Wingboard 1 611 050 04 Accessory Package 1 611 050 05 Accessory Package 1 43 611 095 03 Bracket Support 2...

Страница 62: ...10 97 Page 62 of 64 Use Factory Certified Parts Friedrich Air Conditioning Co 4200 North Pan Am Expressway P O Box 1540 San Antonio Texas 78295 1540 U S A Phone 210 357 4400 Fax 210 357 4480 Printed...

Отзывы: