INTRODUCTION
Model and Serial Number Identification Guides
Figure 105 (Model Identification Guide)
V
R
P
2
4
K
2
5
S
S
A
S
VRP Heat Pump
Series
-A
Engineering code
Reserved for future options
K = 230/208 V
Voltage
R = 265 V
Nominal Capacity (Btu/ Hr.)
36 = 20,000 - 36,000 Operating range
24 =12,000 - 28,000 Operating range
Heater watts
25 = 2.5 kW
34 = 3.4 kW
50 = 5.0 KW
75 = 7.5* kW
Reheat
S= Standard (without); R= Reheat
™
Outdoor Air/ Ventilation** S= Standard unit. No FreshAire
35 CFM for 12,000 BTU and 24,000 BTU Units
80 CFM for 36,000 BTU Units
F= Single OA Fan Powered FreshAire System
10 = 10.0 kW
15= 15.0 kW
0 = 0.0 kw
70 CFM for 12,000 BTU and 24,000 BTU Units
130 CFM for 36,000 BTU Units
Plenum and louver configuration
A= Only for 12000 Btu units
B= For 24000 Btu units (can also be used
for 12000 Btu units)
C= Only for 36000 Btu units
D= Dual OA Fans Powered FreshAire System
12 = 4,000 - 16,000 Operating range
VRP - 12 - K-50 - F - R - A - A - A
YEAR OF MANUFACTURE
17 = 2017 18 = 2018
19 = 2019 20 = 2020
21 = 2021 22 = 2022
MONTH OF MANUFACTURE
01 = JANUARY 07 = JULY
02 = FEBRUARY 08 = AUGUST
03 = MARCH 09 = SEPTEMBER
04 = APRIL 10 = OCTOBER
05 = MAY 11 = NOVEMBER
06 = JUNE 12 = DECEMBER
MANUFACTURING LOCATION
NUMERIC SEQUENCE
FIRST UNIT OF EACH MONTH = 00001
17 12 M 00001
Figure 106 (Serial Number Identification)
Содержание VRP12K
Страница 30: ...30 OPERATION FreshAire Control To engage the FreshAire system flip the switch into the ON position ...
Страница 46: ...46 OPERATION Component Identification Indoor Coil 36k ...
Страница 47: ...47 OPERATION Component Identification Indoor Blower BLDC Counter Clockwise Impeller 600 1300 RPM ...
Страница 48: ...48 OPERATION Component Identification Outdoor Coil Monitored by 1 thermistor ...
Страница 49: ...49 OPERATION Component Identification Outdoor Fan BLDC Variable Speed 600 1000 RPM ...
Страница 53: ...53 OPERATION Component Identification 4 Way Reversing Valve 208 230v Reversing valve assembly ...
Страница 177: ...177 UPDATING VRP FIRMWARE Or ...
Страница 184: ...184 UPDATING VRP FIRMWARE Open zip file Copy to SD Card Insert into SD Card Slot ...
Страница 193: ...193 UPDATING VRP FIRMWARE Retrieving VRP Data Remove SD Card from FMC and Locate DF Folder ...
Страница 194: ...194 UPDATING VRP FIRMWARE Retrieving VRP Data Right Click Data txt Send to Compressed zipped folder ...
Страница 196: ...196 WIRINGDIAGRAMS 12 24K BTU 208 230V 7 5 10 0 KW Figure 801 Wiring Diagram ...
Страница 197: ...197 WIRING DIAGRAMS 12 24K BTU 208 230V 2 5 3 4 5 0 KW Figure 802 Wiring Diagram ...
Страница 198: ...198 WIRING DIAGRAMS 12 24K BTU 265V 2 5 3 4 5 0 kW Figure 803 Wiring Diagram ...
Страница 199: ...199 WIRING DIAGRAMS 12 24K BTU 265V 7 5 10 kW Figure 804 Wiring Diagram ...
Страница 200: ...200 WIRING DIAGRAMS 36K BTU 208 230V Figure 805 Wiring Diagram ...
Страница 214: ...214 PARTS CATALOG 36k Control Box Diagram Figure 906 12 12 11 13 10 8 4 3 2 16 5 6 7 1 9 10 9 10 11 11 14 15 ...