22
Wire Size
Use
ONLY
wiring size recommended for
single outlet branch circuit.
Fuse/Circuit
Use
ONLY
type and size fuse or HACR
Breaker
circuit breaker indicated on unit's rating
plate. Proper
current protection to the unit
is the responsibility of the owner.
Grounding
Unit
MUST
be grounded from branch circuit
through service cord to unit, or through
separate ground wire provided on
permanently connected units. Be sure that
branch circuit or general purpose outlet is
grounded.
Receptacle
The field supplied outlet must match plug on
service cord and be within reach of service
cord.
Do
NOT
alter the service cord or plug. Do
NOT
use an extension cord. Refer to the
table above for proper receptacle and fuse
type.
Circuit Rating
P
lug Face
Appearance
Model
Breaker or T-D Fuse
(NEMA#)
(Facing Blades)
ALL KQ, SQ and XQ MODELS,
KS10J10, KS12J10A, KM14J10, RS10J10, RS12J10A,
RM14J10, SS08J10R, SS09J10B, SS10J10R,
SS12J10AR, SM14J10R, SC06H10D,
125V - 15A
5 - 15P
YQ06J10A, YS09J10,WS07A10D, WS09A10D, WS12A10D
KS12J30A, KM18J30B, RS16J30,
RM19J30, SS12J30B, SS16J30,
250V - 15A
6 - 15P
SM19J30R, WS09A30D, WS12A30D, WS13A30D
KM21J30, KL25J30A, SM21J30B,
SL24J30A, SL28J30A*, ES12J33, EK12J33A,
ES16J33, YS13J33, WE09A33D, WE12A33D,
250V - 20A
6 - 20P
WE13A33D, WY09A33D, WY12A33E
SL33J30, EM19J34, EK18J34B, EL24J35A,
EL33J35, YM18J34A, YL24J35A
250V - 30A
6 - 30P
* Optional 30 Amp Kit (618-869-00) is recommended in 208 Volt power supply areas that fall below 208 Volts.
For more information, call the Friedrich Service Department.
Due to a program of continuing improvement, specifications are subject to change without notice.
INSTALLATION NOTES:
Supply Cord - All with right angle plug 6' on 115V; 5' on 230/208V.
Room air conditioners include accessories for window or thru-wall
installation. TwinTemp models include accessories for thru-wall
installation. Window mounting requires use of optional
accessory kit as listed below:
Electrical Rating T
Electrical Rating T
Electrical Rating T
Electrical Rating T
Electrical Rating Tables
ables
ables
ables
ables
Electric shock hazard.
Electric shock hazard.
Electric shock hazard.
Electric shock hazard.
Electric shock hazard.
Turn off electric power before service or installation.
All electrical connections and wiring MUST be installed by a qualified
electrician and conform to the National Electrical Code and all local
codes which have jurisdiction.
Failure to do so can result in property damage, personal injury and/or
death.
FRIEDRICH AIR CONDITIONING CO
FRIEDRICH AIR CONDITIONING CO
FRIEDRICH AIR CONDITIONING CO
FRIEDRICH AIR CONDITIONING CO
FRIEDRICH AIR CONDITIONING CO.....
Post Office Box 1540
•
San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway
•
San Antonio, Texas 78218-5212
(210) 357-4400
•
FAX (210) 357-4480
Visit us on the Internet at www.friedrich.com
The consumer - through the AHAM Room Air Conditioner
Certification Program - can be certain that the AHAM
Certification Seal accurately states the unit's cooling and
heating capacity rating, the amperes and the energy
efficiency ratio.
Содержание SM21J30A4
Страница 56: ...56 WIRING DIAGRAM FOR MODELS RS10J101 RS10J103 RS12J101 RS12J103 RS15J301 RM18J30 RM15J101 RM18J302 RM18J303...
Страница 57: ...57 Wiring Diagram for Models SQ05J10A 1 SQ06J10A 1 SQ07J10A 1 SQ08J10B 1...
Страница 58: ...58 WIRING DIAGRAM FOR MODELS KQ05J10A 1 KQ05J10A 3 KQ06J10A 1 KQ06J10A 3 KQ08J10A 1 617 581 04...
Страница 59: ...59 WIRING DIAGRAM FOR MODEL YQ06J10A 1 617 581 05...
Страница 60: ...60 WIRING DIAGRAM FOR MODEL SC06H10D...
Страница 62: ...62 WIRING DIAGRAM FOR MODELS SL24J30A 1 SL24J30A 3 SL28J30A 1 SL33J30 2...
Страница 63: ...63 Wiring Diagram for KS KM KL Models...
Страница 64: ...64 WIRING DIAGRAM FOR MODELS ES12J33 ES15J33A EM18J34A EL24J35 EL33J35 EK12J33A EK18J34A 2 EK18J34A 3...
Страница 65: ...65 WIRING DIAGRAM FOR MODELS YS13J33 YM18J34A YL24J35A...
Страница 66: ...66 WIRING DIAGRAM FOR MODEL YS09J10A...