![Friedrich PDE07K Series Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/friedrich/pde07k-series/pde07k-series_service-and-parts-manual_2333324099.webp)
99
PB
TROUBLESHOOTING
Error Codes
No. Malfunction Name Error
Code
A/C Status
Possible Causes
1
Indoor ambient
temperature
sensor is open/
shortcircuited
F1
The unit will not operate.
The unit will stop operation as it
reaches the temperature point.
1.The wiring terminal between indoor ambient
temperature sensor and controller is loosened or
poorly contacted;
2.There is a short circuit due to trip-over of the
parts on controller;
3.Indoor ambient temperature sensor is damaged
(Please check it by referring to the resistance table
for temperature sensor)(15k at 77°F)
4.Main board is broken.
2
Indoor evaporator
temperature
sensor is open/
shortcircuited
F2
Up and down buttons will be
locked. The unit will stop operation
as it reaches the temperature
point.
1.The wiring terminal between indoor evaporator
temperature sensor and controller is loosened or
poorly contacted.
2.There is a short circuit due to the trip-over of the
parts on controller;
3.Indoor evaporator temperature sensor is
damaged. (Please check it by referring to the
resistance table for temperature sensor) (20k
ohms at 77°F).
4.Main board is broken.
3
Outdoor tube
temperature
sensor
is open/
shortcircuited
F4
Unit will not operate.
Up and down buttons will be
locked.
The unit will stop operation as it
reaches the temperature point.
1.The wiring terminal between outdoor tube
temperature sensor and controller is loosened or
poorly contacted;
2.There is a short circuit due to the trip-over of the
parts on controller;
3.Outdoor tube sensor is damaged (Refer to the
resistance table for temperature sensor) (20k
ohms at 77°F).
4.Main board is broken.
4
low temperature
prevention
protection
FP
A/C enters into pure
electric heating mode, and
low temperature protection
is started up.
1.Indoor ambient temperature is lower than
40°F(5°C) continuously.;
2.Indoor ambient temperature sensor is damaged;
3.Main board is broken.
4. (Refer to the resistance table for temperature
sensor) Check thermistor resistance 15k ohms at
77°F
5
Air outlet
temperature
sensor
FJ
Panel control:
The display displays error code
(it is not displayed in unit off
status, but error LED is displayed).
All loads except indoor fan are
turned off under cooling mode;
all loads stop immediately under
heating mode and indoor fan
blows residual heat for 6s at set
fan speed. Wired controller: no
respond Unit will not operate.
Evaporator High temperature
above 136°F for 1 minute. Will
reset at 126°F.
1. Temperature sensor terminal at air outlet is
loose.
2. There is a foreign object on control board, which
causes short circuit.
3. Temperature sensor at air outlet is broken.
4. Mainboard 1 is broken.
5. (Refer to the resistance table for temperature
sensor) Check thermistor resistance 50k ohms at
77°F.
6. Dirty coil
7. Fan motor failure.
Содержание PDE07K Series
Страница 23: ...23 OPERATION DipSwitchFunction 3 4 4 Dip Switch Functions Settings Dip Switch 3 and 4 Disable No Function ...
Страница 39: ...39 UNIT DISASSEMBLY IndoorMotor Wheel HeatingElementAssembly FIGURE 401 Removal of Indoor Fan Wire Harness ...
Страница 41: ...41 UNIT DISASSEMBLY Indoor Motor Wheel Heating Element Assembly FIGURE 403 Removal of Indoor Fan Grommet ...
Страница 42: ...42 UNIT DISASSEMBLY Indoor Motor Wheel Heating Element Assembly Figure 404 Left side Bushing Bushing Housing ...
Страница 47: ...47 UNIT DISASSEMBLY Indoor Motor Wheel Heating Element Assembly Figure 409 Primary Secondary Limits ...
Страница 48: ...48 UNIT DISASSEMBLY OutdoorMotor Blade ShroudAssembly Figure 410 Remove Gussets and Fan Shroud ...
Страница 50: ...50 UNIT DISASSEMBLY ElectronicBoard ElectricalComponentReplacement Figure 412 Remove User Interface ...
Страница 51: ...51 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 413 Remove User Interface ...
Страница 52: ...52 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement FIGURE 414 Low Voltage Connections ...
Страница 53: ...53 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 415 Power Cord and Housing ...
Страница 56: ...56 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 418 Main Board Relay Board ...
Страница 58: ...58 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 420 Transformer ...
Страница 59: ...59 UNIT DISASSEMBLY Electronic Board Electrical Component Replacement Figure 421 Transformer Removed ...
Страница 96: ...96 COMPONENTS TESTING TestingLineVoltage 208 230 265V AC FIGURE 709 LINE VOLTAGE ...