Страница 1: ...MPC Genesis Plus Vintage GB NT MPC 0321 From N 20FR TC 16800 FRIAX industrie in a constant endeavour to improve its products reserves the right to change any information contained in this leaflet wit...

Страница 2: ...gulation box These elements are interconnected by a refrigerant pipe and an electrical connection At the delivery you must nd in your package your Monobloc the installation manual and the accessories...

Страница 3: ...ence to handle refrigerant uids The device must be free of any obstruction at all times to ensure good operation and reduce safety risks Do not puncture any component of the refrigerant circuit Use ca...

Страница 4: ...8 W 3 2 A Air ow cellar side 2m 2m Refrigerant R134A R134A nominal outside temperature 32 C 32 C 8 18 C 8 18 C Weight 45 kg 49 kg 4 4 A Current cooling mode 4 A 5 A 365 m3 h 310 m3 h Temperature setti...

Страница 5: ...ion grille KGS insulate exible duct Accessories S Standard A Accessories Monobloc FRIAX comes with 4 corners of wall mounts A power supply cable 2m 230V single phase A box with wireless remote table s...

Страница 6: ...ain 16 Operating principal Power fuse holder switch o Inside cellar Evaporator Outside cellar condenser Outisde 32 C Cellar 12 C Condenser Evaporator KCH C o m p r e s s o r MPC Genesis Vintage Humidi...

Страница 7: ...chanical ventilation should be avoided in the cellar Ensure that the hot air is discharged into a venti lated and sheltered room Check the strength of the wall on which the unit is attached Respect th...

Страница 8: ...bloc body is adapted to be xed at 5 di erent depths of recess In certain positions and depending on the material of the wall it may be necessary to add reinforcements to prevent the unit from tipping...

Страница 9: ...ssential when the water pressure is above 2 8bars 9 1 2 Outside the Cellar Inside the Cellar A B C D E E F G H A Kits KLPWSECU Optional kits 3 4 F KLPWSECU Secure connection kit for humidifier HGR A 1...

Страница 10: ...ontrol could be installed in any room Its maximum range is 100m in a completely open area This distance could be extremly reduced by thickness of walls and the location of the cellar It is possible to...

Страница 11: ...re or humidity indicator option Battery charge level indicator C F or humidity unit indicator Speed condensor fan Speed evaporator fan Time 12 AM PM or 24 h existing if EC evaporator fan existing if E...

Страница 12: ...the value with or Access to menu Parameters Display Handling See below the value set according to the device Login with Shorten the waiting period hold Start the unit with the remote control The unit...

Страница 13: ...setpoint tempera ture Returns to the display of measured values in the cellar OK con rm with OK con rm with Change the value with or Change the value with or Step III Set the cellar temperature and h...

Страница 14: ...mal speed Manipulation buttons no longer possible to change the settings Buttons are accessible to change the settings The screen turns o after a few seconds The appliance continues to operate The scr...

Страница 15: ...AM PM display on 24 Access to menu Parameters Display Handling OK OK con rm with Change the value with or Login with OK OK con rm with Change the value with or Login with OK OK con rm with OK con rm...

Страница 16: ...s set to 0 at the factory It may be modi ed only in the case where there would be a gap between the moisture displayed and the real humi dity of the cellar Only available on model Vintage Lets ventila...

Страница 17: ...nit motor fan type 2 type 2 Radio signal lost type 1 AS1c A SL A SH A SO AS2c A SL A SH AHRH A SO AS3c AS3H AS3O AVEc AVCc A rF Faulty outside unit motor fan Upper threshold wine cellar temperature Lo...

Страница 18: ...temperature and humidity Restart the unit With the remote Press For 2 seconds Unit starts If symbol or ashes unit is in stand by mode Press until or become xed Press simultaneously OK Push 10 Seconds...

Страница 19: ...ensor on Vintage series GND PWM1 TAC CP HGR KCH EVF CDF POWER Sonde cond T L L L L L N N N N N blue Yellow White Blue Blue Black Black 5 x 20 10A GT L N T HGR or On Vintage model L N L N EVF RC L N L...

Страница 20: ...the front panel using an Allen key to access the air condenser battery Use a vacuum cleaner to remove dust Be careful not to damage the fins Check that there are no leaves or any other object that co...

Страница 21: ...accordance with applicable local and national regulations Used units and batteries must be treated in specialized repair reuse facilities or recycling By ensuring this device is disposed of properly...

Страница 22: ...22 NOTES...

Страница 23: ...LOWING EUROPEAN MEASURES AND THEIR MODIFICATION 9 2014 35 EU Basse Tension 9 2014 35 EU Low Voltage 9 2014 30 EU Compatibilit lectromagn tique 9 2014 30 EU Electromagnetic compatibility 9 2014 68 EU E...

Страница 24: ...Site web www friax fr Boite mail friax fr info 231 233 Rue de la Prairie F 73420 Voglans D couvrez notre de cave de rangement pour la cave site web www visiorack com...