7. Disassembly and recycling

Necessary tools

• 

Screwdrivers or screw removers. Torx, 

Phillips and hexagonal

• 

Polygrip input

• 

Wrench

• 

Hammer 

• 

Pliers

Disassembly/Assembly

Open hatches/doors using the unit’s key.

Remove filters, fans, heat exchangers, batteries, etc.

Release fans from mounting plates (wrench).

Section

Material

Handling

Panels and doors

Plate AZ185 and rock wool 

insulation

Recycling after separation

Metal parts

Plate AZ185, steel, galvanized steel, 

powder-coated steel

Recycling

Heat exchanger (air-air)

Aluminium, steel

Recycling after separation

Air heater

steel, galvanized steel (composite)

Recycling after separation

Sealing strip, vibration damping

EPDM

Energy recovery (heat plant)

Air filter

Fibreglass media, galvanized steel 

frame

Energy recovery (heat plant) 

after separation

Fastening material

Galvanized steel, aluminium

Recycling

Sealing compound

Acrylic, MS Polymer

Energy recovery (heat plant)

Muffler material

Synthetic fibre

Energy recovery (heat plant)

Motors

Composite

Recycling after separation

Control and electrical components

Composite, electrical products

Recycling by authorised company

Packaging

Wood, plastic film, card, cardboard Recycling, Heat recovery

Содержание FRX 110S

Страница 1: ...www fresh se FRX 110S 200S INSTALLATION DISASSEMBLY Swedish manufactured heat recovery units E kodesign 20 1 6 ErP 2016...

Страница 2: ...ntenance 6 06 Disassembly and recycling 7 08 Warranty All equipment manufactured by us is trialled and tested before leaving the factory and is sent in good condition We provide a 2 year warranty from...

Страница 3: ...st not be used for any other purpose Do not use the unit in explosive environments or in connection with combustible aggressive and easily flammable gases Never use the unit without a filter Prior to...

Страница 4: ...m Bag filter On the supply air class F7 filters are used and on the extract air a class M5 bag filter is used Dimensions FRX 110S mm Dimensions FRX 200S mm 3 Technical data Connection options The pict...

Страница 5: ...ical data Capacity The diagram shows the maximum external pressure to comply with the Ecodesign requirement this applies to electric heaters when using water heaters or coolers assume this has a press...

Страница 6: ...noise problems Ensure that supply and exhaust air ducts are suitably insulated to avoid condensation Frequency band 63 125 250 500 1000 2000 4000 8000 Total Total sound level 68 To environment 46 36 3...

Страница 7: ...emoved by disconnecting the quick connector and then removing the battery If the manual overheating protection fails the unit must be disconnected from the mains electricity supply Wait until the heat...

Страница 8: ...fans from mounting plates wrench Section Material Handling Panels and doors Plate AZ185 and rock wool insulation Recycling after separation Metal parts Plate AZ185 steel galvanized steel powder coate...

Отзывы: