MAINTENANCE

 

 

4.1  INSPECTION & SERVICING 

 

Routine  servicing,  at  least  annually,  is  highly  recommended  in  order  to  maintain  the  safe 
operation  of  the  chair.    Any  faults  or  warranty  claims  should  be  reported  immediately  to  the 
manufacturer  or  its  agent.  No  liability  can  be  accepted  by  the  manufacturer  if  the  chair  is 
operated whilst faulty and further damage occurs. 

Areas to be checked include:  

 

No broken welds 

 

Upholstery not worn or torn 

4.2  CLEANING  

Cleaning  should  conform  to  the  standards  set  by  the  hospital.  All  materials  used  in  the 
manufacture of the chairs have been found to be suitable to be cleaned with standard hospital 
cleaning  products,  however  to  ensure  suitability,  a  test  should  first  be  carried  out  on  an 
inconspicuous piece of material, or a sample provided by the manufacturer. 

The  following  should  be  used  as  a  guideline  only  and  no  claims  will  be  accepted  for 
damage or otherwise from following these guidelines: 

 

RECOMMENDED CLEANING PROCEDURE FOR MEDICAL TREATMENT CHAIRS 

The following recommended procedure should only be used if it generally conforms to 
Infection Control Guidelines of the hospital.

 

Step 1 

Bodily fluids may carry infectious material.  Ensure that 

protective  garments  and  gloves  are  worn  prior  to 
commencing the cleaning operation. 

 

 

Step 2 

Remove as much of the spilt liquid as possible using a 

sponge-type material with a dabbing motion. 

 

 

Step 3 

Make  up  a 

diluted

  bleach  solution  (e.g.  Miltons)  of  1 

part bleach to 30 parts water.  

 

 

Step 4 

First  test  the  solution

  on  a  small  area  of  the  vinyl.  

Then,  pour  onto  spill  area  and  wipe  with  a  mopping 
action. 

 

 

Step 5 

Use  a  general  purpose  detergent  cleaner  with  warm 

water on a cloth for a final clean. 

 

CAUTIONARY NOTES ABOUT BLEACH

 

1. 

Never allow bleach to mix with ammonia.

 If you have recently used ammonia on or 

near the area you are about to clean, 

do not use bleach.

  

2.  Always take care when working with bleach and keep it away from children. Bleach is 

not only poisonous and corrosive, but it can damage clothes and materials.  

3. 

Never use undiluted bleach

.

 

 

4.3  FABRIC STANDARDS

 

Unless  otherwise  stated,  standard  upholstery  fabrics  used  on  these  chairs  conform  to  the 
following Australian Standards: 

Flame Retardant tested to AS1530.30* 

Cigarette Burn test AS 37441.1* 

UV stabilised AS1441.1* 

*NOTE:  This  is  for  Fresenius  Medical  Care  Seating-supplied  fabric.  Customer-specific  fabric 
may not meet these standards. 
 

 

Содержание T200 Series

Страница 1: ...Medical Treatment Chair T200 T300 Series Instruction Manual ...

Страница 2: ...5 Reporting Serious Incident 2 2 OPERATING THE MEDICAL TREATMENT CHAIR 3 3 INSTALLING THE MEDICAL TREATMENT CHAIR 4 3 1 WARNINGS AND PRECAUTIONS 4 4 MAINTENANCE 5 4 1 INSPECTION SERVICING 5 4 2 CLEANING 5 4 3 FABRIC STANDARDS 5 5 ARRANGING A SERVICE 6 6 WARRANTY INFORMATION 7 7 PHYSICAL DESCRIPTION 8 7 1 DESCRIPTION OF DEVICE 8 7 2 TECHNICAL SPECIFICATIONS 8 7 2 1 Dimensions 8 7 2 2 Operating Cond...

Страница 3: ...ted before moving the chair It is the staff members responsibility to ensure the patient is briefed on the safe operation of the chair For T200 and T300 models with CPR legs fitted In an emergency the chair can be lowered to the Trendelenburg position where CPR may be performed It is the staff members responsibility to ensure that the chair is in the correct position for CPR and that the resuscita...

Страница 4: ...T200 T300 series only put the back release lever located below the rear arm pad into the release position allowing the backrest to move to the required position Relock as required 4 Fold out tray arm if fitted is accessed by opening the upper section outwards 5 Lift up tray tables if fitted lift up and lock into place 6 To allow the patient to rise from the chair return it to the upright position ...

Страница 5: ...vers on until the chairs are in their intended operating position Note Transport damage if any should be inspected and reported immediately after delivery No claims for transport damage will be accepted 7 days after delivery date 3 1 WARNINGS AND PRECAUTIONS The following table shows potential hazards that have been identified and the steps that should be taken to avoid them IDENTIFIED HAZARD CAUS...

Страница 6: ...dure should only be used if it generally conforms to Infection Control Guidelines of the hospital Step 1 Bodily fluids may carry infectious material Ensure that protective garments and gloves are worn prior to commencing the cleaning operation Step 2 Remove as much of the spilt liquid as possible using a sponge type material with a dabbing motion Step 3 Make up a diluted bleach solution e g Milton...

Страница 7: ... serial number or your purchase order number when requesting a service The serial number can be found on the label attached to the rear of the chair An example of the label is in section 7 2 4 CONTACT INFORMATION https fmc seating com MANUFACTURER SERVICE CENTRE FRESENIUS MEDICAL CARE SEATING AUSTRALIA PTY LTD 786 Stud Road SCORESBY VICTORIA 3179 AUSTRALIA sales seatingAU fmc asia com SERVICE TEL ...

Страница 8: ...reseller this warranty covers costs at the premises of the reseller and if required in approved situations transport costs from the reseller to and from Melbourne or to some other party 4 Use of non recommended cleaning agents may void the warranty 5 The T200 T300 Series Medical Treatment Chairs are covered under a 12 month warranty 6 The T200 T300 Series Medical Treatment Chairs are not covered b...

Страница 9: ...g castors legrest reclining backrest T300 Medical Treatment Chair consists of Manually operated chair with adjustable headrest central locking castors legrest reclining backrest slide out footrest 7 2 TECHNICAL SPECIFICATIONS 7 2 1 Dimensions Model Dimensions T200 T300 Height 110 cm 115 cm Width 83 cm 83 cm Length 90 cm 90 cm Weight 41 kg 58 kg Capacity 130 kg 130 kg 7 2 2 Operating Conditions No ...

Страница 10: ...le Number Catalog Number Date of manufacture Serial Number CE mark Manufacturer For indoor use only Caution warning Consult Instruction Manual authorized representative in the European Community Medical Device Authorised Representative in the European Community Fresenius Medical Care Deutschland GmbH Else Kröner Straße 1 61352 Bad Homburg Germany Telephone 49 6172 609 0 ...

Страница 11: ...Fresenius Medical Care Seating Australia Pty Ltd 786 Stud Road Scoresby VIC 3179 Australia IFUT 100 T200 T300 EN V5 April 2021 ...

Отзывы: