Chapter 13: Definitions
Fresenius Medical Care multiFiltrate IFU-EN-UK 15A-2015
13-1
13 Definitions
13.1 Terms
Filtrate or filtrate flow
Filtrate or filtrate flow is the sum total of the dialysate, substituate, net
UF, citrate flow, and calcium flow. The filtrate or filtrate flow forms the
basis for the calculation of the calcium flow and is internally calculated
by the system.
Acute haemodialysis
treatment
Acute haemodialysis is the application of a hemodialysis therapy for the
treatment of temporary renal failure or acute exogenous poisoning.
Alarm function check
The alarm function check is the verification of the proper function of the
alarm equipment.
Alarm limit
The alarm limit is the measurement value which, when exceeded, will
trigger an alarm.
Arterial section
The arterial section is the section of the extracorporeal circuit from the
patient to the dialyser inlet port.
Arterial pressure
The arterial pressure is the pressure present at a defined site in the
arterial section between the vascular access and the pump.
Exchange volume
The exchange volume is the fluid volume removed from the blood by
filtration which is replaced with substituate at a ratio of 1:1.
(The respective rate is indicated in ml/h or ml/min.)
The respective rate is the indicator at which speed the exchange is
performed.
Treatment time
The treatment time is the amount of time during which balancing is
switched on.
Blood leak monitor
The blood leak monitor is a device used to detect blood in the filtrate or
dialysate, e.g., consisting of a sensor (detector), alarm generator, and
a sensitivity indicator, and controller, if necessary.
Blood pump
The blood pump is provided to transport the blood in the extracorporeal
circuit.
Calcium pump
The calcium pump is used for adding calcium solution to the patient’s
blood.
Calcium dose
The calcium dose is the volume of calcium solution added to the
patient’s blood in relation to the filtrate or filtrate flow. The dose is
specified in mmol per litre of filtrate (filtrate flow).
Calcium flow
The calcium flow is the volume of calcium solution supplied to the
patient’s blood per time unit.
Содержание multiFiltrate
Страница 1: ...multiFiltrate Instructions for Use Software version 5 3 Edition 15A 2015 Part no M56 963 1 ...
Страница 2: ......
Страница 11: ...Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 xi 15 2 Instructions on the use of free software 15 2 ...
Страница 12: ...xii Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 16: ...Chapter 1 Index 1 4 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 42: ...Chapter 3 Design 3 10 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 166: ...Chapter 4 Operation 4 124 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 Interrupting the treatment ...
Страница 186: ...Chapter 5 Alarm processing 5 20 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 188: ...Chapter 6 Cleaning disinfection 6 2 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 218: ...Chapter 7 Functional description 7 30 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 228: ...Chapter 9 Installation 9 4 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 234: ...Chapter 11 Technical Safety Checks maintenance procedures 11 2 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 252: ...Chapter 12 Specifications 12 18 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 260: ...Chapter 13 Definitions 13 8 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 266: ...Chapter 14 Options 14 6 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...
Страница 282: ...Chapter 15 Appendix 15 16 Fresenius Medical Care multiFiltrate IFU EN UK 15A 2015 ...