freor PLUTON SPACE Скачать руководство пользователя страница 34

 

34 

 

17.

 

 TECHNICAL DATA 

17.1.

 

 Technical information 

 
Annex 1 

17.2.

 

 Electrical layouts 

 
Find inside electric box.  

17.3.

 

 Control settings 

 
Annex 1 

17.4.

 

 Setting of values of the control functions 

 
Annex 1 

17.5.

 

 Failures and troubleshooting 

 

Repair of the internal freezing coil of the showecase, checking of the 
refrigerant amount and replacement of parts may only be carried out 
by a specialist qualified to work with F and OAM gases.  
Only  an  electrician  with  the  respective  qualification  may  carry  out 
inspection and repair of electrical installation.  

The control informs on faults of the semi vertical Pluton Space. 

Alarm  
code

buzze r and 
alarm  re lay

LED

alarm  de s cription

re s e t

ENABLE ALARM 
param e te rs  
involve d

E0

active

ON

probe 1 error= control

automatic

-

E1

not active

ON

probe 2 error= def rost

automatic

d0= 0 / 1 / 4, F0= 1

E2

not active

ON

probe 3 error= condenser/product

automatic

[A4=10/11] 

IA

active

ON

external alarm

automatic

[A4 = 1] [+A7]

dOr

active

ON

open door alarm

automatic

 [A4=7/8][+A7] 

LO

active

ON

low  temperature alarm

automatic

[AL] [Ad]

HI

active

ON

high temperature alarm

automatic

[AH] [Ad]

EE

not active

ON

unit parameter error

not possible

-

EF

not active

ON

operating parameter error

manual

-

Ed

not active

ON

def rost ended by timeout

on f irst def rost 
ended correctly

[dP] [dt] [d4] [A8]

dF

not active

OFF

def rost running

automatic

[d6=0]

cht

not active

ON

dirty condenser pre-alarm

automatic

 [A4=10] 

CHt

active

ON

dirty condenser alarm

manual

 [A4=10] 

EtC

not active

ON

clock alarm

by setting the time

if  bands are active

Содержание PLUTON SPACE

Страница 1: ...OPERATION MANUAL SEMI VERTICAL PLUTON SPACE...

Страница 2: ...LATION OF THE SEMI VERTICAL PLUTON SPACE 13 4 INSTALLATION OF THE PLUTON SPACE ISLAND 21 5 ACCESS TO THE COMPRESSOR IN THE EVENT OF FAILURE 25 6 CONNECTION OF THE POWER SUPPLY 28 7 GENERAL INSTRUCTION...

Страница 3: ...17 TECHNICAL DATA 34 17 1 Technical information 34 17 2 Electrical layouts 34 17 3 Control settings 34 17 4 Setting of values of the control functions 34 17 5 Failures and troubleshooting 34 18 MEANI...

Страница 4: ...er information Manufacturer address UAB FREOR LT Katiliskiu St 92 LT 02212 Vilnius Lithuania Phone 37052329188 EN Made in Lithuania Customer Installation date Installation place Start of the product o...

Страница 5: ...ticker Fig 1 Labelling table Fig 1 Example of the labelling sticker The instructions are purposed for maintenance and operation of the semi vertical Pluton Space The unit is equipped in accordance wit...

Страница 6: ...6 1 2 Dimensions Fig 2 Dimensions of Pluton Space 8 Fig 3 Dimensions of Pluton Space 7 Fig 4 Dimensions of Pluton Space 6...

Страница 7: ...7 Fig 5 Dimensions of Pluton Space Island 6 plug in...

Страница 8: ...8 1 3 Packaging and its dismounting Unload the semi vertical Unscrew the self cutting screw M6x100 ISO 7380 Remove the unit from the pallet x 2 Size 10 15 min...

Страница 9: ...gnited mixture of gas and air Only the manufacturer s approved electrical devices may be used for shelves of food products The refrigeration system may be operated only by maintenance personnel author...

Страница 10: ...iry products delicacies ready made food snacks sandwiches green salad game salad with mayonnaise sauce cooked meat products eggs and their products sauces 4 C Household poultry minced meat and product...

Страница 11: ...ment in front of heating radiators heaters and near air outlets Do not direct the heat sources or spot radiators such as incandescent lamps to the unit Any heat emitted to the unit increases operating...

Страница 12: ...es the maximum allowable loads are specified in the main layout sticker example in fig 3 The sticker is attached to right corner of inner ceiling It is forbidden to exceed the indicated maximum loads...

Страница 13: ...13 3 INSTALLATION OF THE SEMI VERTICAL PLUTON SPACE X2 Size 17 32 Install plastic legs Apply silicone and screw the nozzle into the condensate drainage opening...

Страница 14: ...ount the transportation profile Using the front and rear legs perform horizontal and vertical pre adjustment of the semi vertical The leg is adjustable in 5 cm Using the level perform horizontal and v...

Страница 15: ...15 Insert the guides as shown in the figure With the adhesive foam tape seal connection gaps Apply silicone to seal the connection gaps...

Страница 16: ...f the guides and put together the furniture To achieve a more robust connection compress the cabinet legs Insert threaded rods with washers into the indicated places and tighten them with the wrench T...

Страница 17: ...indicated places and tighten it with the wrench Threaded rod M10x90 ISO 7985 Insert threaded rod with washers into the indicated places and tighten it with the wrench Threaded rod M10x90 ISO 7985 Sea...

Страница 18: ...18 Insert the cover onto the indicated place Take the bracket to install the lower dust cover Insert the threaded staples as shown in the figure Secure brackets on the legs...

Страница 19: ...19 Secure the threaded staples to the dust cover Connect the dust covers using the self cutting screws M4x13 ISO 7380 Put on the dust covers and fasten them with the self cutting screws M4x13 ISO 7380...

Страница 20: ...20 Using a rubber hammer attach the rubber bumper...

Страница 21: ...21 4 INSTALLATION OF THE PLUTON SPACE ISLAND Size 8 Insert the guides as shown in the figure With the adhesive foam tape seal connection gaps...

Страница 22: ...y silicone to seal connection gaps Perform the final match of the guides and put together the furniture Insert the self cutting screws M4 8x19 ISO 1479 into indicated places and tighten them using the...

Страница 23: ...1479 into indicated places and tighten them using the wrench Seal the bottom connection joints with silicone Put on the condensing block on the top of the semi vertical It is necessary to pay attenti...

Страница 24: ...g block fastening it with the self cutting screws M4 8x19 ISO 1479 Put on the end dust cover and tighten the self cutting screws 2x13 ISO 7380 Put on the front dust covers and tighten the self cutting...

Страница 25: ...25 Using a rubber hammer attach the rubber bumper 5 ACCESS TO THE COMPRESSOR IN THE EVENT OF FAILURE Open the door Remove the air intake grille...

Страница 26: ...26 Remove the bottom shelves Unscrew screws and remove the bottom tin plate of the wall Unscrew screws and remove the tin plate of the wall...

Страница 27: ...27 Unscrew the screws of the compressor cover Remove the compressor cover...

Страница 28: ...ormance of the semi vertical Excess humidity in the premise can cause occurrence of condensate on cold surfaces of the semi vertical The semi vertical has to be protected against exposure to sunlight...

Страница 29: ...open semi verticals should be covered with curtains 7 2 Operation The semi verticals Pluton Space are installed in the shopping premises at a predefined location The cabinets have to be interconnecte...

Страница 30: ...Evaporators have to be regularly defrosted in accordance with programs set in the control During the defrosting refrigeration is not run Evaporators of high temperature cabinets can be defrosted usin...

Страница 31: ...nded to use special detergents purposed for dyed surfaces After washing the surfaces must be well dried up The paint damage can cause metal corrosion at the scratch place Glass parts can be washed usi...

Страница 32: ...quest of the customer the semi verticals can be supplied with a door or mechanical night curtains During non business hours of the shop open showcases must be closed with the night curtains Make sure...

Страница 33: ...ting it is necessary to remove all transportation fasteners screws and packages After transportation of the semi verticals to the facility carefully inspect the whole equipment and all its components...

Страница 34: ...description reset ENABLE ALARM parameters involved E0 active ON probe 1 error control automatic E1 not active ON probe 2 error defrost automatic d0 0 1 4 F0 1 E2 not active ON probe 3 error condenser...

Страница 35: ...the freezer compartments Contamination of the freezing coil Damage of the tightness of the freezing coil Failure of the control valve TRV ERV Leakage of the refrigerant Call the refrigeration technici...

Страница 36: ...nged phases one phase cabinet elements can be operational Check switches Check the network The compressor is out of order Refrigeration cycle disorders Signals of the pressure sensors Fluctuations of...

Страница 37: ...37 18 MEANINGS OF SYMBOLS Symbol Meaning Type Qualified specialist Work clothing Protective gloves Wrench Sizes 8 10 17 32 Screwdriver Rubber hammer Protective goggles Silicone pistol Clamp...

Страница 38: ...38 Date Work Name...

Страница 39: ...39 Date Work Name...

Страница 40: ...ufacturer of the commercial refrigeration equipment Katiliskiu St 92 LT 02212 Vilnius Lithuania T 370 5 232 9188 E sales freor com www freor com DOM 3CX0X X0000E_v1 1 FREOR LT is not affiliated with C...