15
5.
INSTALLATION
5.1.
Requirements for installation the multideck
Installation of the unit must be performed following next requirements:
•
The unit must be aligned horizontally (both depth and length) and installed in
the stable position.
•
Set up the unit only on the designated adjustable legs.
•
It is forbidden to install the unit close to any heating equipment or any HVAC
elements (air outlet etc.).
•
Keep a sufficient distance around the unit. It must be possible to open the doors
without any obstructions.
o
The exhaust air must be able to escape freely at the top of the unit.
o
Minimum clearance from ceiling 500 mm. Lower minimum clearance must
be approved by the manufacturer.
o
Superstructures or false ceilings directly on top of the unit should only be
installed after consultation with the manufacturer.
•
To allow warm air to escape, there must be a gap of at least 150 mm between
the ceiling and all hanging billboards. Lower minimum gap only in agreement
with the manufacturer.
Fig.7.
Example of unsuitable ambient conditions