Страница 2: ...ntrol Unit 4 Big Flow Blowing Junction Block 5 Identification 6 Application 6 Mounting 6 Supply of Air or Water Pressure 7 Blowing a Fiber Cable into a Duct 7 Preparing for Blowing 7 Use of Compressed Air for Blowing 8 Use of Water for Blowing 8 Maintenance 9 Safety Directions 10 Format and Wear Parts 10 Recommended Accessories 10 EC Declaration of Conformity 11 ...

Страница 3: ...al size of the fiber cables microducts and ducts in question PowerFlow Manufacturer Fremco A S Ellehammervej 14 9900 Frederikshavn Denmark Item No 101 10001 Cable microduct diameter 8 25 mm Duct diameter 18 70 mm Blowing distance Up to 10 km Blowing speed Up to 80 m min Recommended water pressure 10 20 bar Recommended pressure and airflow 8 12 bar 8 000 12 000 l pr min Weight 38 kg Length 650 mm W...

Страница 4: ...aulic Control Unit Manufacturer Fremco A S Ellehammervej 14 9900 Frederikshavn Denmark Item No 103 10041 Hydraulic connection 0 125 bar 17 l min Manometer 160 bar Hose to fiber blowing machine 1500 mm Hose to hydraulic pump 1500 mm Length 250 mm Width 250 mm Height 310 mm Weight 5 kg ...

Страница 5: ...ight protected 5 Big Flow Blowing Junction Block For blowing multiple microducts or single cable Manufacturer Fremco A S Ellehammervej 14 9900 Frederikshavn Denmark Item No 103 130424001 Length 270 mm Width 100 mm Height without connection pipe 230 mm Weight 5 kg ...

Страница 6: ... length with an extra piece of duct and a connector Connect the hydraulic MultiPower Pack to the hydraulic control unit Make sure to place the Powerflow machine on a stable foundation and to fasten it to withstand the forces which occur during use These push pull forces can be up to 125 kg Be careful to avoid any dirt on the surfaces when mounting the duct into the blowing junction block Tighten t...

Страница 7: ...make sure that all format parts fit the number and diameter of the microducts cable and duct Preparing for Blowing Arrange the cable drum equipment approx 10 m in front of the Powerflow Check that the drum can turn easily and that the setup is stable Start the hydraulic MultiPower Pack for cable blowing machines Adjust to 50 75 power and let it run 2 5 minutes Connect the hoses from the hydraulic ...

Страница 8: ...ock gradually CAUTION Check continuously that the drum turns smoothly If not check the pressure of the top chain on the fiber cable Intensify if necessary Use of Water for Blowing Connect the duct to the blowing junction block Connect the suction tube from the water pump to the water supply Start the engine on the water pump and let it run for approximately 4 5 min Connect the pressure tube from t...

Страница 9: ...bricant The chains should be tightened to an extent that the they can be lifted only 5 10 mm from the support rail The chain support rails must be replaced when the side plates on the chain touch the support rails It is very important to avoid any kind of dirt in the hydraulic connectors when mounting the hydraulic hoses If the machine is not to be used for a longer period of time it should be cle...

Страница 10: ...risk getting your fingers injured and make sure the microducts or the cable do not make loops that might be dangerous to people around the machine Use hearing protection if the hydraulic pump or other noisy equipment is placed nearby The joystick on the hydraulic control unit should never be blocked in a way where it is unable to return to neutral position The operator must make sure that no other...

Страница 11: ...e hereby declare that 101 10001 Powerflow Blowing Machine for cables is manufactured in conformity with the EC Directives 2006 42 EC Fremco A S Ellehammervej 14 DK 9900 Frederikshavn Denmark Niels Søgaard Hansen General Manager 01 04 2012 Fremco A S Ellehammervej 14 9900 Frederikshavn Denmark Tel 45 72 30 12 13 ...