   NanoFlow MAX

  

   

 

    For fiber dimension 0.8-4.5 mm        

    

 

 
 
 

Operating manual  

 

 

Responsible manufacturer: Fremco A/S 
Machine: NanoFlow MAX 

 

 

 

This is the original operating manual for NanoFlow MAX from Fremco. 

 

 

Содержание 101-190911001

Страница 1: ...N DENMARK VAT NO DK30815416 TELEPHONE 45 7230 1213 SALES FREMCO DK WWW FREMCO DK THIS MATERIAL IS COPYRIGHT PROTECTED NanoFlow MAX For fiber dimension 0 8 4 5 mm Operating manual Responsible manufactu...

Страница 2: ...ONS 6 4 SAFETY INSTRUCTIONS 7 5 MAINTENANCE 7 6 IDENTIFICATION 8 7 APPLICATION 8 8 MOUNTING 8 9 SUPPLY OF COMPRESSED AIR 8 10 FIBER PROTECTION 9 11 MACHINE OVERVIEW 10 12 RUNNING THE FIBER BLOWING MAC...

Страница 3: ...tically included when you purchase your Fremco fiber blowing machine you automatically get our 12 months warranty You can then claim your additional 24 months warranty at any point during the followin...

Страница 4: ...pplicable from machine serial number 9328 3023 Accessibility The instructions are to be kept in a location known to the staff and must be easily accessible for the operators and maintenance personnel...

Страница 5: ...name Fremco A S Company address Ellehammervej 14 DK 9900 Frederikshavn 2 2 THE MACHINE S DESIGNATION The machine s complete designation is NanoFlow MAX 2 3 MACHINE PLATE The machine plate is situated...

Страница 6: ...Denmark Item No 101 190911001 Fiber diameter 0 8 4 5 mm Duct diameter 3 12 7 mm Blowing distance Up to 1200 m 3940 ft Blowing speed Up to 125 m min 410 ft min Pushing force 0 2 kg Maximum air pressure...

Страница 7: ...ecause you risk getting your fingers injured and make sure the fiber does not make loops that might be dangerous to persons around the machine Never wear loose clothing WARNING Loose clothing may beco...

Страница 8: ...mes in a carrying case When the machine is not in use or during transportation always store it in the carrying case Charge the battery before operation 8 MOUNTING Make sure to place the machine on a s...

Страница 9: ...iction in the duct The higher setting of torque the later this will happen At a point the blowing will stop as it is no longer possible to push the fiber with the chosen torque setting The display on...

Страница 10: ...815416 TELEPHONE 45 7230 1213 SALES FREMCO DK WWW FREMCO DK 11 MACHINE OVERVIEW Adaptor Plates Inlet Guides Main Power Switch Step Switch Machine runs only when the Step switch is actuated Torque knob...

Страница 11: ...5416 TELEPHONE 45 7230 1213 SALES FREMCO DK WWW FREMCO DK NB Too high clamping force can cause fiber damage After every fiber blowing deployment job the clamping force has to be reset to 1 This secure...

Страница 12: ...uct quality of compressed air blowing length weather conditions etc Lift the support wheel and push the fiber in between the wheels approx 15 cm Release the support wheel to let it fall into place thu...

Страница 13: ...move towards a stop and activate the fiber safety Valve for reverse airflow For removal of fiber from a duct use the valve to blow compressed air through the duct so that the fiber can be pulled out A...

Страница 14: ...nd duct adaptors fit the actual size of the fiber and the duct Below is an overview of the different adaptor components for NanoFlow MAX Many different sizes of adaptor plates and duct adaptors for ma...

Страница 15: ...E CHANGING ADAPTOR PLATES Preparation of adaptor kit for correct fiber and duct size Choose the correct size of adaptor plate to suit the fiber Choose the correct size of duct adaptor to suit the duct...

Страница 16: ...the wheels are mounted correctly Make sure that machine and wheels are clean and free from grease and dirt The adaptor plates are not identical One is for the top and one is for the bottom The design...

Страница 17: ...DK Like the adaptor plates the inlet guides are not identical One is for the top and one is for the bottom Like the adaptor plates the inlet guides must be at least 0 2 mm larger than the fiber Examp...

Страница 18: ...Item No 103 160601064 1 Attach the water separator on the compressor s discharge nozzle 2 Attach air hose on the separator s discharge nozzle 3 Attach the opposite end of the air hose on the machine...

Страница 19: ...lectromagnetic disturbance 2014 35 EU The LowVoltage Directive The directive ensures that electrical equipment within certain voltage limits provides a high level of protection for European citizens a...

Страница 20: ...s are placed on the GB market by requiring manufacturers to show how their products meet the essential requirements 2016 No 1101 Electrical Equipment Safety regulations 2016 International standards DS...

Отзывы: