background image

Tera Term Activation and ZumLink Setup

Note

: The images in this procedure are for Windows® 7 and/or Firefox®.

The dialog boxes and windows appear differently on each computer.

1.

On the computer connected to the ZumLink device, open a terminal
program (e.g., Tera Term

http://ttssh2.osdn.jp/

).

2.

In Tera Term, on the

File

menu, select

New Connection

.

Figure 6: File menu > New Connection

The

Tera Term New Connection

dialog box opens.

3.

Click the

Port

list box arrow and select the COM port the ZumLink device is

connected to.

Figure 7: Select the Z9-PE-DEVKIT COM port

Important!

: The

Port

assignment varies from computer to computer.

4.

Click

OK

to save the changes and close the dialog box.

The Tera Term window shows the connected COM port and Baud rate in
the title bar of the window.

5.

In the Tera Term window, click the

Setup

menu and select

Serial Port

.

Figure 8: Serial menu > Setup Port

The

Tera Term: Serial Port Setup

dialog box opens with the default

ZumLink settings.

Figure 9: Tera Term: Serial Port Setup dialog box with default

settings

6.

Verify the COM port settings are:

Baud Rate

: 115200

Data

: 8 bit

Parity

: none

Stop

: 1 bit

7.

Click

OK

to save the changes and close the dialog box.

8.

In the Tera Term window, press <Enter>.
The ZumLink CLI Login returns.

9.

Type

admin

to login and press <Enter>.

10.

When prompted, type

admin

for the password and press <Enter>.

Note

: The password does not appear when typing - it looks blank.

The

FreeWave Shell

returns.

Figure 10: The FreeWave Shell returns.

11.

At the > prompt, type

ip_address=192.168.1.nnn

and press <Enter>.

12.

At the > prompt, type

nodeId=nnn

and press <Enter>.

Note

: Where

nnn

= the same unique 3 digit number.

13.

At the > prompt, type

save

and press <Enter>.

Note

: Go to

http://support.freewave.com/

to login and download the latest

firmware for the Z9-PE-DEVKIT..
Registration is required to use this login.

Learn More

For additional product information about the Z9-PE-DEVKIT, visit

http://support.freewave.com/

.

For additional assistance, contact a local reseller, or contact FreeWave Technologies, Inc. at 303.381.9200 or
1.866.923.6168, or by email at

[email protected]

.

FreeWave Technologies, Inc. reserves the right to make changes to this document or the product described
within it without notice. FreeWave assumes no responsibility or liability for the use of this document or the
infringement of any copyright or other proprietary right.

The ZumLink Z9-PE-DEVKIT complies with FCC Part 15 rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful interference and 2) this device must accept any
interference received, including interference that may cause undesired operation.

FreeWave Technologies, Inc.
5395 Pearl Parkway, Suite 100
Boulder CO 80301

www.freewave.com

Local: 303.381.9200
Toll Free: 1.866.923.6168
Fax: 303.786.9948

QSG0052AA Rev Oct-2017

Page 2 of 2

Copyright © 2017 FreeWave

Отзывы: