Figure 2.2.7.2.3.3-1 Submenu after pressing DMR soft key in Monitor mode
The nominal deviation points for each data symbol are as follows:
Bits Symbol Deviation
01
+3
+1944 Hz
00
+1
+648 Hz
10
-1
-648 Hz
11
-3
-1944 Hz
Table 2.2.7.2.3.3-1. DMR Symbols
2.2.7.2.4
DMR receiver tests
DMR receiver tests are performed with the R8100 in Generate mode and protocol specific tests are
accessed with the DMR soft key - see Figure 3.2.8.3.2-1. The R8100 generates DMR compliant test
patterns and can be adjusted over a wide range of RF levels to determine the sensitivity and data
ransmission integrity of the DMR radio. DMR submenu selections are as follows: