AutoTune for Motorola APX Series Radios User Guide
58
7. Basic Troubleshooting
Symptom
Possible Cause(s) Possible Solution(s)
Radio repeatedly fails
communication
initialization.
Serial link corruption. Retry communicating with the
radio after each of the following
steps:
•
Power cycle the radio.
•
Restart the analyzer.
Radio powered off
Power on radio
Programming cable
unconnected
Connect programming cable
Mobile radio won’t power
up.
Loose HKN6163_
cable connection.
Verify cable connection is OK.
Motorola CPS
Ignition Switch
setting.
Use Motorola CPS software to
set Radio Wide, Advanced,
Ignition Switch setting to “Blank”.
This setting lets radio power up
for testing without an ignition
signal present. Be sure to return
this setting to its original value
when testing completed.
Portable radio consistently
fails TX Power Out test
and/or alignment.
DC Power supply
current limiting
preventing portable
radio from getting
adequate current.
Adjust DC power supply current
limit to at least 3 Amps.
Table 7-1. AutoTune Troubleshooting Chart