28
FPQ41 Superminor Issue 1
6
Cleaning and maintenance
This section describes how to clean and maintain
the Superminor.
Make sure the Superminor is
disconnected from the power supply
before you carry out any cleaning or
maintenance.
Bacteria that have been filtered from
the coolant could pose a bio-hazard.
Wear the correct PPE including
protective gloves and eye protection
and take care when dealing with the
used filter bags and all coolant.
Toxic substances such as coolant can
cause skin and eye irritation. Wear the
appropriate PPE and follow company
procedures at all times.
Sharp pieces of metal will be filtered
from the coolant. Take care when
emptying and cleaning the filters.
6.1
Regular checks
The following checks are
recommendations based on an average
of 2 hours use per day. If the
Superminor is used more heavily, then
the weekly and monthly checks should
be carried out more often.
6.1.1
After each use
Empty the Superminor fully each time it is used.
This will prevent sediment build-up.
Section 4.9.
Change the filter (if disposable) or clean the filter
(if reusable)
Section 4.2
Section 6.2.1.
Check the seal around the filter basket rim is not
damaged.
Replace the seal if necessary.