FRC BRYTTE DAY OPA740 Скачать руководство пользователя страница 1

OPA740 Rev1108

1

FIRE RESEARCH CORPORATION

www.fireresearch.com

26 Southern Blvd., Nesconset, NY11767

TEL  ( 631 ) 724-8888  FAX  ( 631 ) 360-9727  

TOLL  FREE  1-800-645-0074

BRYTTE DAY

PORTABLE LIGHTING

SYSTEM

MODELS: OPA740, OPA742,

 OPA756, OPA769

Document Number:

XM-OPA74PM-R0A

HPA100

Power Pack

Standard with all

Brytte Day Systems

OPA742

Shown with optional 

tripod carry handle.

OPA740

Matches the OPA700 

Portable with a HPA100 

Power Pack

Содержание BRYTTE DAY OPA740

Страница 1: ... 8888 FAX 631 360 9727 TOLL FREE 1 800 645 0074 BRYTTE DAY PORTABLE LIGHTING SYSTEM MODELS OPA740 OPA742 OPA756 OPA769 Document Number XM OPA74PM R0A HPA100 Power Pack Standard with all Brytte Day Systems OPA742 Shown with optional tripod carry handle OPA740 Matches the OPA700 Portable with a HPA100 Power Pack ...

Страница 2: ...ND INDICATORS 7 ASSEMBLE 8 Set Up 8 Break Down 8 OPERATION 10 Emergency Back Up Mode 11 Power Up 12 Charge Store Battery 13 MAINTENANCE 14 Bulb Replacement 14 Cleaning 14 List of Figures and Tables Figure 1 Controls and Indicators 7 Figure 2 Assemble 9 Figure 3 Operation 10 Table 1 Battery Charge Levels 12 Figure 4 Bulb Replacement 15 ...

Страница 3: ...e telescopic pole in position quick and easy An internal brake lowers the pole slowly on a cushion of air This helps to prevent pinched fingers and damage to the bulb An optional tripod carry handle is available for OPA742 and OPA756 models Power Pack HPA100 The Power Pack battery charger unit includes a 100 maintenance free sealed AGM battery and a microprocessor controlled charger that are housed...

Страница 4: ...50 LUMENS Dimensions Width 9 Depth 9 Including Wire Guard Height 13 Tripod Material Anodized Aluminum Folded Lengths OPA742 OPA756 OPA469 with Lamphead 42 56 69 w o Lamphead 32 46 59 Extended Height 62 90 115 Removable lamphead is optional Accessories Removable Lamphead Option Vinyl Carrying Bag for Lamphead w Removable Lamphead Option Tripod Carry Handle OPA742 and OPA756 Only Safety Features Wir...

Страница 5: ...176 to 264 VAC Option 240 VAC Unit Charger Supply Current 3A at 120 VAC 2A at 240 VAC Typical Dimensions Width 11 Depth 6 1 2 Height 12 Weight 32 6 LBS 12V battery 35 6 LBS 24V battey Accessories AC Power Charge Cord Connector Options for 240 VAC Cord DC Charging Cord 12 VDC w Cigarette Lighter Plug 24 VDC w pigtails Safety Features Non Spillable Battery Built in Over Current Protection Built in O...

Страница 6: ...ely hot when operating do not use such that personnel or equipment could inadvertently come in contact with the lamphead Operation Safety Precautions Ensure that all lighting components are clear of obstructions when raising telescopic poles Maintenance Safety Precautions Refer to Maintenance section for procedures Ensure power is off prior to removing the front glass or opening covers Do not oper...

Страница 7: ...and when the battery is charging or in storage Refer to Operation Section CHARGING DISCHARGING LEDs These LEDs indicate that the battery is charging or discharging When the Power Pack is connected to an AC power source the CHARGING LED will be on OVERHEATING LED Flashes to indicates an over heat condition ON OFF Switch This switch supplies DC voltage to the DC output connector The green LED above ...

Страница 8: ...HARGING LED comes on When the battery is trickle charging the CHARGING LED blinks 6 Adjust the lamphead angle then loosen the twist lock to raise the telescopic pole Tighten the twist lock to hold the pole in position Break Down 1 Press the ON OFF button The green LED and the DISCHARGING LED go off The light goes off 2 If connected to an AC source the AC cord can be removed or left connected to ch...

Страница 9: ... DC connector for lamphead power cord Also used when charging from a DC power source Twist Lock Used to Raise and Lower Telescopic Pole or Rotate the Lamphead Leg Bracket Knurled Knob Secures legs in position Leg Bracket Tripod Legs Telescopic Pole Shown Raised Figure 2 Assemble ...

Страница 10: ...is provides for continuous use of the light and recharges the battery at the same time Not letting the battery run down completely light goes out extends the life of the battery To ensure the battery is fully charged when needed it is recommended that the Power Pack be stored plugged in to an AC or DC source in the charge mode This allows for a constant trickle charge When the battery is trickle c...

Страница 11: ...d In this mode the light operates normally Press the ON OFF button the green LED is on and the CHARGING LED is on The lamphead light comes on Press the ON OFF button again the green LED and the lamphead light go off When AC power is lost The lamphead light automatically comes on The CHARGING LED goes off and the DISCHARGING LED comes on The amber MED and green FULL LEDs continue to alternately bli...

Страница 12: ...rce the CHARGING LED is on 3 Loosen the lamphead knurled knob to tilt the lamphead to desired angle 4 Loosen the twist lock to extend the telescopic pole or rotate the lamphead tighten the twist lock to hold in position Checking the Charge Level Note No charging cords should be connected for the LEDs to give a correct indication of the battery charge level Press the CHECK CHARGE LEVEL button One o...

Страница 13: ... and switches over into trickle charging the CHARGING LED blinks The light can be connected and operated while the Power Pack is connected to an AC source charging the battery When programmed for the Emergency Back Up Mode refer to Operation Section the Power Pack charges normally and monitors the facility power via the AC charging cord IfAC power is lost the BrytteDay light automatically comes on...

Страница 14: ...prints can cause damage the quartz bulb If the bulb is accidently touched gently wipe it clean with alcohol 6 Check both lamp base contacts to be sure they are perfectly clean 7 Push one end of the bulb into the spring contact until the other end can be placed into the opposite contact Rotate the lamp back and forth about its axis to ensure adequate seating of contacts Caution Do not operate the l...

Страница 15: ...OPTIMUM LAMPHEAD CAUTION Position the glass inside the housing lip on all four sides Failure to do so may result in cracking the glass when the screws are tightened Lip Glass Housing Lip Housing Glass Bulb Screw Bezel The Wire Guard is Not Shown ...