18
Overload alarm (continued)
A
Remove the extractable.
Remove the black plastic
cap from the PMA end bell.
Use an Allen wrench to
manually spin the PMA rotor.
Replace the PMA, and reinstall the extractable.
Does the motor
spin freely?
Yes
No
Contact
FFS Tech
Support.
Turn on power to the smart controller.
Recalibrate the SPGC-220 with the new PMA.
Monitor for proper operation.
Yes
No
Was the
calibration
successful?
Contact
FFS Tech
Support.