2

 

The electrical power outlet required for this pump is a 
separate 15 amp circuit of 115 volts, AC 60HZ, with a 
proper fused switch in the line.  This must be located 
within 8 feet of the pump. The ground terminal on the 
plug is provided for your protection. Do not remove.

 

Plug the pump cord into the 115 volt grounded service 
and connect the discharge piping, your pump is then 
ready for operation.

3) 

Sump Preparation Requirements:

 

a)  level bottom - can be levelled with bricks.

 

b)  size: minimum 24" deep x minimum 12" diameter 

(Note: pump will operate more effi ciently in an 18" 
diameter sump.)

4) 

Float Switch: 

(where applicable)

 The 

fl oat switch (if so equipped) is sealed and factory 

adjusted to be suitable for most sumps. Be sure that 
the fl oat has adequate clearance and cannot become 
stuck on the sides of the sump. Do not allow the cord to 
interfere with the free movement of the fl oat or to drape 
over the motor housing. The cord should be taped to 
the pump discharge  piping with electricians tape. 

 

NOTE: 

Range of pumping levels can be varied by 

adjusting the free length of cable between the fl oat switch 
and the cable clamp.  The free length of cable must be 
at least 4" to allow free movement of the fl oat. Longer 
free length allows a larger pumping range.  Always check 
operation of switch after making any adjustments!

5) 

Discharge Piping:

 

a)  The pump has a threaded discharge opening.

 

b)  PVC or ABS adapters may be used to adapt to  

other sizes of pipe.

 

c)  We recommend that you not reduce the discharge 

pipe size, use as large as possible.

 

d)  Keep piping length to a minimum (extra length 

increases friction losses).

 

e)  A check valve must be installed for proper 

installation.

FIG. 1  - TYPICAL INSTALLATION

The free length of cable 
must be at least 4" to 
allow free movement of 
the fl oat.

Check valve

6)  

Operational Check:

 (never operate pump dry)

 

Upon installation manually fi ll the sump to check the 
fl oat switch operation.  Ensure the start and stop levels 
are satisfactory and the fl oat has adequate clearance 
to the sump sides.  While the pump is operating check 
that all connections are tight and are not leaking.

 

IMPORTANT: 

To avoid freezing in the discharge line 

during cold weather operation drill a 1/4" hole in the 
discharge pipe above the check valve in sump pit. This 
will allow any liquid in the discharge pipe to drain back 
into the sump pit and avoid freezing.

 If 

the 

back 

fl ow of water in the discharge pipe causes 

the pump to turn on again, then the length of the 
discharge pipe needs to be reduced.

If the pump is placed into the water while running, it will air 
lock.  This means that air is trapped in the pump, preventing 
it from pumping water.  To avoid this, always place the pump 

in the water when it is off, and then plug it in.  If the pump 
does air lock, simply unplug it and then plug it back in.

AIR LOCKING

Automatic Models

 

The pump operation is designed to be completely 
automatic, the integral switch (if so equipped) is preset 
at the factory to turn the pump on and off when the fl uid 
level in the tank reaches a specifi c height. Separate, 
piggyback-style switches must be carefully adjusted 

during installation to ensure proper operation.

Manual Models

 

Plug in and unplug the electrical cord as required or 
use a certifi ed control for starting and stopping, of equal 
or greater horsepower rating than the pump.

OPERATION

Your pump has been built to give many years of satisfactory 
service. No regular maintenance is required since the 
pump is completely self lubricating.  The following routine 
checking procedure is recommended to be carried out 
once a year and is especially important for occasional use 
applications.

 

a)  Check the power cords and electrical outlet for 

damage or corrosion.

 

b)  Ensure there is no build-up of sludge or sediment 

in the sump.

 c) 

Manually 

fi ll the sump to check for correct switch 

adjustment and pump operation.

MAINTENANCE

Содержание SP25A

Страница 1: ...for grounding connect only to properly grounded receptacle Do not under any circumstances remove ground plug Keep electric plug dry Do not lift pump using cord Not investigated for use in swimming pool area A ground fault interrupter GFI protected circuit is recommended for use with any electrical appliance operating in or near water SAFETY CAREFULLY READ THE SAFETY MESSAGES IN THIS MANUAL AND ON ...

Страница 2: ... Upon installation manually fill the sump to check the float switch operation Ensure the start and stop levels are satisfactory and the float has adequate clearance to the sump sides While the pump is operating check that all connections are tight and are not leaking IMPORTANT To avoid freezing in the discharge line during cold weather operation drill a 1 4 hole in the discharge pipe above the che...

Страница 3: ...USE REMEDY Motor does not run Blown fuse Replace fuse Tripped circuit Reset Disconnected plug Reinstall Corroded plug Clean prongs Tripped overload Allow pump to cool investigate cause jammed impeller Defective switch Replace switch Defective motor Replace pump repair Float improper position Check for freedom of movement Motor hums but flow reduced or none at all Impeller jammed Remove bottom plat...

Страница 4: ...designed and manufactured 2 Product not installed in accordance with applicable codes ordinances and good trade practices 3 Product connected to voltage other than indicated on nameplate 4 Pump exposed to but not limited to the following sand gravel cement grease plaster mud tar hydrocarbons or hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances 5 Pump has b...

Страница 5: ...s eaux de puisards lorsque les exigences totales de la tête de pompe pertes de charge par frottement comprises ne sont pas conformes ou excèdent la capacité maximale de la pompe ou lorsque la dimension maximale des solides est inférieure à sa capacité d absorption Parfaite pour drainage de caves NE JAMAIS UTILISER POUR DES EAUX DE RUISSELLEMENT Avant l installation vérifiez les codes d électricité...

Страница 6: ...S pour la raccorder à d autres grosseurs de tuyau c Nous vous conseillons de ne pas réduire le diamètre du tuyau de sortie Employez un tuyau aussi gros que possible d Gardez la longueur de la tuyauterie au minimum Plus la conduite est longue plus les pertes par FIG 1 INSTALLATION TYPIQUE Le montant de cablage entre la flotte et le serre câble doit être un minimum de 4 pour ne pas impêcher le move ...

Страница 7: ...cédure de vérification suivante recommandée une fois l an est extrêmement importante en vue d utilisations spéciales éventuelles a Vérifiez les cordons d alimentation et le système de branchement en prévision de dommage ou corrosion possible b Assurez vous qu aucune accumulation de boues ou de sédiments n est présente dans le puisard c Remplissez manuellement le puisard pour vérifier le réglage ap...

Страница 8: ...é 2 Le produit n est pas installé dans le respect des codes et règlements applicables et selon les bonnes pratiques acceptées dans l industrie 3 Le produit a été branché à une tension autre que celle indiquée sur la plaque signalétique 4 La pompe a été exposée entre autres aux produits suivants sable gravier ciment graisse plâtre boue goudron hydrocarbures dérivés d hydrocarbure huile essence solv...

Страница 9: ...e Estas bombas son para aplicaciones de agua de letrinas en las que el requerimiento total de presión incluyendo las pérdidas por fricción de tuberías no excede la capacidad máxima de la bomba Asimismo el tamaño máximo de los sólidos no debe ser mayor que la capacidad de la bomba Esta bomba es para usarse como desagüe para sótanos o bodegas NO ES PARA USARSE EN APLICACIONES EFLUENTES O DE AGUAS CL...

Страница 10: ...tubería de descarga use una tan grande como sea posible d Mantenga el largo de la tubería al mínimo un largo FIG 1 INSTALACIÓN TÍPICA La parte del cable entre el interruptor y la abrazadera no debe sur menos de 4 para que el mevi mieato dep flotador sea libre mayor aumentará la pérdida por fricción e Para una instalación adecuada se debe incluir una válvula de retención 6 Revisión de Operación Nun...

Страница 11: ...ción de sedi mento en la letrina c Llene la letrina manualmente para verificar el correc to ajuste del interruptor y la operación de la bomba MAINTENIMIENTO PROBLEMA CAUSA PROBABLE ACCIÓN CORRECTIVA El motor no prende Fusible quemado Reemplace el fusible Circuito desenganchado Vuelva a enganchar Enchufe desconectado Vuelva a instalar Enchufe con corrosión Limpie las clavijas Sobrecarga desengancha...

Страница 12: ... conformidad con las normas reglamentos y prácticas comerciales aceptadas 3 El producto se conecta a un voltaje distinto al que se indica en la placa de identificación 4 La bomba se expone a lo siguiente pero sin limitarse a ello arena grava cemento grasa yeso barro brea hidrocarburos o sus derivados aceite gasolina solvente etc u otras sustancias abrasivas o corrosivas 5 La bomba se ha utilizado ...

Отзывы: