INTRODUCTION

This instruction sheet provides you with the information required to safely own and 

operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and 

material, and has been engineered to give you long and reliable service. These 

products are carefully tested, inspected, and packaged to ensure safe delivery 

and operation. Please examine your item(s) carefully to ensure that no damage 

occurred during shipment. If damage has occurred, please contact the place of 

purchase. They will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT’S 

APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 

YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. 

FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN 

PERSONAL INJURY AND/OR PROPERTY DAMAGE!

SAFETY GUIDELINES

WARNING:

 When attaching pump leads to battery terminals, be sure that the area is 

adequately ventilated to prevent an explosion or fire from explosive or flammable 

vapors that may be present. Consult the battery manufacturer for additional safety 

information.
Disconnect the pump from the power source before servicing or removing any 

component.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, 

kerosene, etc. Do not use in explosive atmospheres. Pump should only be used 

with liquids compatible with pump component materials.
Do not handle pump with wet hands or when standing on a wet or damp surface 

or in water.
Batteries emit explosive hydrogen gas. Avoid smoking, sparks, or open flame 

anywhere near the battery.
An explosion from the battery can cause blindness. Shield your eyes when 

working near the battery. 
Batteries contain sulfuric acid. In case of contact with eyes, skin, or clothing, flush 

immediately with large amounts of water and get medical attention. 
Do not add acid or electrolyte to the battery. 
Keep out of reach of children.
In any installation where property damage and/or personal injury might result 

from an inoperative or leaking pump due to power outages, discharge line 

blockage, or any other reason, use a backup system(s) and/or alarm.
Support the pump and its piping when assembling and when installed. Failure to 

do so may cause piping to break, pump to fall, motor bearing failures, etc.

ELECTRICAL CONNECTIONS

 1.  Check the pump label for proper voltage required. Do not connect to voltage 

other than that shown.

 2.  For proper motor protection, install a 2.0 amp fuse in the circuit.
 3.  When using a battery as the power source, attach the red positive (+) lead 

wire to the positive (+) battery terminal, then attach the black negative (-) 

lead wire to the ground (-) battery terminal. When disconnecting the pump, 

first disconnect the black negative (-) lead wire from the ground (-) battery 

terminal, then disconnect the red positive (+) lead wire from the positive (+) 

battery terminal.

 4.  Refer to Table 1 for recommended minimum lead wire sizes.

DISTANCE FROM POWER SOURCE 

TO PUMP

RECOMMENDED MINIMUM WIRE 

SIZE

1 – 15 feet

18 AWG

15 – 50 feet

16 AWG

Table 1

1

OPERATION

CAUTION:

 This pump is designed for intermittent use only (15 minutes on – 45 

minutes off) with liquid no hotter than 160°F.

CAUTION:

 The pump is cooled by pumping fluid. Do not let the pump operate 

dry; this can damage the seal and cause motor failure.

NOTE:

 This pump is designed to operate submerged or in-line. It can be placed 

in any position below the water level when primed.
  1.  For proper operation, connect the pump to a steady 12-volt DC power source 

or a 12-volt battery in good condition. A low-voltage power source may cause 

critical overheating and premature failures. To avoid this, maintain proper 

voltage and use recommended wire size during installation (Table 1).

 2.  Use the hooded inlet plate for submersible operation. For in-line operation, 

remove the inlet plate mounting screws and replace the hooded inlet plate with 

the threaded inlet plate. Make certain that the inlet O-ring seal is installed in the 

groove on the inlet plate before reassembly. Carefully reinsert the mounting 

screws, taking care not to cut new threads or strip the screw holes.

 3.  When connected in-line, slope the hose or pipe connection upward from the 

pump inlet to the water supply. A flooded suction is necessary for pump to 

operate.

  4.  If the surface is dirt or sand, place the pump on a flat object (such as a piece of 

wood or metal) to prevent it from being clogged.

 5.  Support the weight of the pump adequately. DO NOT support the pump by 

the intake or discharge connections alone.

  6.  Do not restrict the intake side of the pump. This can damage the seal and starve 

the pump. To reduce the flow, place a valve on the discharge side of the pump 

or, if flexible vinyl tubing is used, a clamp on the tubing.

 7.  If the pump will be idle for an extended period, clean it according to the 

MAINTENANCE section. Do not let the pump freeze in the wintertime. This 

can cause cracking or distortion that will damage the pump.

MAINTENANCE

WARNING:

 DISCONNECT THE PUMP FROM THE POWER SOURCE BEFORE 

SERVICING OR REMOVING ANY COMPONENT.

CAUTION:

 The pump is permanently lubricated. Oiling is not required. DO NOT 

open the sealed portion of the pump or remove the housing screws. 

NOTE:

 The power leads on this pump cannot be replaced; if they become 

damaged the entire pump must be replaced.
Clean the pump periodically to prolong its life and efficiency:
 1.  Disconnect the black negative (–) lead wire, then disconnect the red positive 

(+) lead wire.

 2.  Check the lead wires to ensure that they are in good condition with no nicks 

or cuts.

 3.  Remove the volute mounting screws, then remove the volute from the pump. 

DO NOT remove any other screws.

 4.  Lightly clean any corrosion or debris that may clog the impeller. Use a brush 

and penetrating oil and lightly scrape to remove encrusted material.

 5.  Turn the impeller by hand to make sure it turns freely. 
 6.  Place the pump on a solid surface, ensuring that the pump and impeller are 

not touching anything. Connect the pump to 12VDC power source for 10 

seconds. If the impeller rotates, disconnect the pump from the power source 

and install the parts in reverse order. If the impeller does not rotate or the 

pump does not operate properly, return the pump to Franklin Electric or an 

authorized service center. DO NOT attempt repairs yourself.

Figure 1