background image

SAFETY INSTRUCTIONS

Before Getting Started

2

SAFETY INSTRUCTIONS

Before Getting Started

This equipment should be installed and serviced by technically qualified 

personnel. Failure to comply with national and local electrical and 

plumbing codes and within Franklin Electric recommendations may 

result in electrical shock or fire hazard, unsatisfactory performance, or 

equipment failure.
Know the product’s application, limitations, and potential hazards. Read 

and follow instructions carefully to avoid injury and property damage. 

Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating 

instructions and specifications.
Failure to follow installation/operation procedures and all applicable 

codes may result in the following hazards:

Risk of death, personal injury, or property 

damage due to explosion, fire, or electric shock.

Do not use to pump flammable or explosive fluids such as gaso

-

line, fuel oil, kerosene, etc.

Do not use in explosive atmospheres or hazardous locations as 
classified by the NEC, ANSI/NFPA70.

Do not handle a pump or pump motor with wet hands or when 
standing on a wet or damp surface, or in water.

When a pump is in its application, do not touch the motor, pipes, 
or water until the unit is unplugged or electrically disconnected.

If the power disconnect is out of sight, lock it in the open posi

-

tion and tag it to prevent unexpected application of power.

If the disconnect panel is not accessible, contact the electric 
company to stop service.

High voltages capable of causing severe 

injury or death by electrical shock are 

present in this unit.

To reduce risk of electrical shock, disconnect power before work

-

ing on or around the system. More than one disconnect switch 
may be required to de-energize the equipment before servicing.

This product is supplied with a grounding conductor and ground

-

ing-type attachment plug. To reduce risk of electric shock, be cer

-

tain that it is connected only to a properly grounded grounding-
type receptacle. Do not remove the third prong from the plug. The 
third prong is to ground the pump to help prevent possible electric 
shock hazard. Do not use an extension cord.

Check electrical outlets with a circuit analyzer to ensure power, 
neutral, and ground wires are properly connected. If not, a qual

-

ified, licensed electrician should correct the problem.

Wire pump system for correct voltages.

The pump has been evaluated for use with water only. Pump 
should only be used with liquids compatible with pump compo

-

nent materials. If the pump is used with liquids incompatible 
with the pump components, the liquid can cause failure to the 
electrical insulation system resulting in electrical shock.

Risk of bodily injury, electric shock, or 

equipment damage.

This equipment must not be used by children or persons with 
reduced physical, sensory or mental abilities, or lacking in expe

-

rience and expertise, unless supervised or instructed. Children 
may not use the equipment, nor may they play with the unit or 
in the immediate vicinity.

Equipment can start automatically. Always unplug the pump 
power cord and disconnect the electrical power before servicing 
the pump or switch. 

An inoperative or malfunctioning pump could lead to flooding, 
resulting in personal injury or property damage.

In applications where property damage and/or personal injury 
might result from an inoperative or leaking pump due to power 
outages, discharge line blockage, or any other reason, an auto

-

matic back-up system and/or an alarm should be installed.

Do not run the pump dry. If run dry, the surface temperature of 
the pump will rise to a high temperature that could cause skin 
burns if touched and will cause serious damage to the pump.

Do not oil the motor. The pump’s motor housing is sealed, and 
contains a high-grade dielectric oil for heat transfer and lifetime 
lubrication. Use of other oils could cause serious electric shock 
and/or permanent damage to the pump.

Operation of this equipment requires detailed installation and 
operation instructions provided in this manual for use with this 
product. Read entire manual before starting installation and oper

-

ation. End User should receive and retain manual for future use.

Keep safety labels clean and in good condition.

Risk of damage to pump or other equipment.

Do not use this pump for pumping sea water, beverages, acids, 
chemical solutions, or any other liquid that promotes corrosion 
as this can result in damage to the pump.

Do not run pump dry. For optimal cooling and to prolong the 
motor life, the liquid level being pumped should normally be 
above the top of the pump housing.

This pump is not suitable for pond applications.

Содержание Little GIANT 10ECH Series

Страница 1: ...FETY INSTRUCTIONS 2 INTRODUCTION 3 Product Description 3 Specifications 3 INSTALLATION 4 Physical Installation 4 Electrical Connections 6 OPERATION TESTING 6 Testing Automatic Pump Operation 7 Testing...

Страница 2: ...lyzer to ensure power neutral and ground wires are properly connected If not a qual ified licensed electrician should correct the problem Wire pump system for correct voltages The pump has been evalua...

Страница 3: ...printed copy Please examine your item s carefully to ensure that no damage occurred during shipment If damage has occurred please contact the place of purchase They will assist you in replacement or r...

Страница 4: ...nd piping while assembling and when installed Failure to do so may cause the piping to break the pump to fail motor bearing failures etc Always install a union in the discharge line just above the bas...

Страница 5: ...Typical Installation 1 2 3 4 5 6 7 8 9 10 11 12 1 Gate Valve 4 Switch Power 7 Discharge 10 Caulking Hub 2 Check Valve 5 Pump Power 8 Gas Tight Basin 11 3 16 Air Bleed Hole 3 Union 6 Vent 9 Intake 12...

Страница 6: ...mp is allowed to run dry Pump should be totally submerged for proper cooling of the motor when pump is operated for extended periods Pump HP Voltage VAC Breaker Amps 9EC 4 10 115 15 9ECH 4 10 115 15 1...

Страница 7: ...served To test system operation follow these steps 1 Plug the power cord into a grounded receptacle with voltage consistent with the pump voltage as indi cated on the pump nameplate 2 Be sure the gate...

Страница 8: ...to the pump Do not overfill the basin or test reservoir 6 If the pump is provided with an attachment plug on the power cord plug the pump s power cord into a ground fault circuit interrupter GFCI rec...

Страница 9: ...from the air bleed hole If not clear the hole of any deposits or debris Cleaning Impeller and Volute Periodic cleaning of the pump parts will prolong the life and efficiency of the pump Refer to the a...

Страница 10: ...e check valve and inspect for proper operation Lift too high for pump Check rated pump performance Inlet to impeller plugged Pull pump and clean Pump is air locked Remove pump and clean air bleed hole...

Страница 11: ...Parts Number Part Number Description 1 599210 599121 599209 RF Series Piggyback Float Switch 115 V 20 FT Cord RF Series Piggyback Float Switch 115 V 30 FT Cord RF Series Piggyback Float Switch 230 V 2...

Страница 12: ...Franklin Electric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com For technical assistance please contact Form 998781 Rev 000 11 19...

Страница 13: ...RIDAD 2 INTRODUCCI N 3 Descripci n del producto 3 Especificaciones 3 INSTALLACI N 4 Instalaci n fisica 4 Instalaci n t pica 5 Conexiones el ctricass 6 PRUEBA DE OPERACI N 6 Pruebas de funcionamiento d...

Страница 14: ...con conexi n a tierra Para reducir el riesgo de descarga el ctrica aseg rese que se conecte solo a un recept culo del tipo con conexi n a tierra que est conectado apropiadamente a tierra La tercer pun...

Страница 15: ...egiant com o bien llame al departamento de Soporte t cnico para obtener una copia impresa Examine su bomba en forma minuciosa para asegurarse de que no haya sufrido da os durante el env o Si sufri da...

Страница 16: ...liza la tuber a se puede romper la bomba puede tener fallas los cojinetes del motor pueden tener fallas etc Siempre instale una uni n en la l nea de descarga justo por encima de la cubierta del recipi...

Страница 17: ...ador enchufe de ali mentaci n 7 Descarga 10 Cubo de calafateo 2 V lvula de retenci n 5 Enchufe de ali mentaci n de la bomba 8 Dep sitoimpermeable a los gases 11 Orificio de purga de aire de 3 16 pulg...

Страница 18: ...da para estar refrigerada mediante el bombeo de l quido Si la bomba funciona en seco es posible que da e el sello y que el motor falle Las bombas est n equipadas con un interruptor de flotador atado o...

Страница 19: ...ptor se puede observar Para probar la operaci n del sistema siga estos pasos 1 Conecte la bomba a un suministro de energ a adecuado que tenga un voltaje congruente con el voltaje de la bomba como se i...

Страница 20: ...eta ni el dep sito de prueba 6 Si la bomba viene con un enchufe de seguridad en el cable de alimentaci n enchufe el cable de alimentaci n de la bomba a un recept culo con un interruptor de circuito po...

Страница 21: ...itos o residuos Limpiar el impulsor y la voluta Al limpiar peri dicamente las piezas de la bomba se prolongar la vida til y la eficiencia de la bomba Consulte el ensamblaje y el desmontaje del cabezal...

Страница 22: ...ara comprobar que funcione bien Elevaci n demasiado alta para la bomba Revise el desempe o nominal de la bomba Entrada al impulsor obstruido Quite la bomba y l mpiela La bomba est obturada por aire Si...

Страница 23: ...mero de parte Descripci n 1 599210 599121 599209 RF Flotante Remoto 115 V Cable de alimentaci n de 20 pies RF Flotante Remoto 115 V Cable de alimentaci n de 30 pies RF Flotante Remoto 230 V Cable de...

Страница 24: ...Franklin Electric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com For technical assistance please contact Form 998781 Rev 000 11 19...

Страница 25: ...ES DE S CURIT 2 INTRODUCTION 3 Description du produit 3 Sp cifications 3 INSTALLATION 4 Installation physique 4 Installation typique 5 Branchements lectriques 6 TEST DE FONCTIONNEMENT 6 Test de Foncti...

Страница 26: ...ache de mise la terre Pour r duire le risque de d charge lectrique assurez vous de seulement brancher la pompe une prise lec trique correctement mise la terre Ne retirez pas la troisi me branche de la...

Страница 27: ...ements complets sur la garantie consulter le site www littlegiant com ou communiquer avec le soutien technique pour en obtenir une copie imprim e Examiner soigneusement la pompe pour s assurer qu elle...

Страница 28: ...entra ner la rupture des tuyaux la d faillance de la pompe la d faillance des paliers du moteur etc Installez toujours un raccord union dans le conduit de refoulement juste au dessus du couvercle de b...

Страница 29: ...11 12 1 Clapet de la vanne 4 Corde de pouvoir de Changement de Flotteur 7 Tuyau de sortie 10 Collet d tanch it Orifice de prise d air 2 Clapet de retenue 5 Corde de pouvoir de pompe 8 Bassin tanche au...

Страница 30: ...tilis e pendant une certaine p riode suivez les instructions de nettoyage pr sent es dans la prochaine section Ne laissez pas l unit geler Cela peut causer des fissures ou des distorsions qui peuvent...

Страница 31: ...absence de toute fuite dans la plomberie de refoulement de la pompe et dans le tuyau de drainage principal de la maison REMARQUE Il est normal qu un filet d eau s chappe de l orifice de prise d air d...

Страница 32: ...cle de l orifice d un boulon situ la base de l appareil Assurez vous que ce filet est recueilli l int rieur du bassin 8 Si la pompe ne fonctionne pas comme pr vu d branchez le cordon d alimentation de...

Страница 33: ...u remplacez les composants touch s 4 Confirmez que les colliers de serrage de tous les raccords flexibles sont correctement fix s et bien serr s 5 Testez le fonctionnement du syst me Se r f rer TEST D...

Страница 34: ...vation est trop lev e pour la pompe V rifiez le tableau des valeurs nominales L aspiration vers l impulseur est obstru e Retirez la pompe et nettoyez la La pompe est bloqu e par de l air Enlever la po...

Страница 35: ...e Description de pi ce 1 599210 599121 599209 RF Flotteur Distance 115 V Cordon d alimentation de 20 pieds RF Flotteur Distance 115 V Cordon d alimentation de 30 pieds RF Flotteur Distance 230 V Cordo...

Страница 36: ...Franklin Electric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Form 998781 R v 000 11 19...

Отзывы: