Страница 1: ...Franke omni DUO Boiling water system Installation User Guide...

Страница 2: ...RECT INSTALLATION The Franke Omni System comprises 3 separately packaged assemblies 1 Franke Omni Duo tap Part Number 119 0513 245 2 Franke boiler Model QHT 1 Part Number 119 0380 581 3 Franke water f...

Страница 3: ...al power supply is required you must seek the services of a qualified electrician The boiler must only be connected to the 230V mains electricity supply through either an earthed independent wall sock...

Страница 4: ...4 nuts x2 11 NutRunna hand tightening device for G1 2 nuts x4 12 Omni QHT 1 Boiler 13 Push fit elbow 14 Flat Silicone Washers for boiler water inlet outlet x2 15 Vent Assembly 16 Saddle Clamp 17 Vent...

Страница 5: ...he cabinet slide the gasket 8 and the clamp plate 5 over the hoses and the stud at the base of the tap Screw the clamp nut 6 on to the stud using the box spanner 7 5 Check the alignment of the tap the...

Страница 6: ...sump leading to eventual failure 1 Position the filter unit 20 vertically with the hoses at the top in its previously determined location 2 Mark the positions for the two filter unit support screws 22...

Страница 7: ...bly and enough room to operate the pipe cutter 19 1 Separate the two halves of the saddle clamp by unscrewing and removing the four nuts and bolts Discard the two black rubber inserts for 41mm waste p...

Страница 8: ...caps from the three connections on the top of the boiler 2 Place the boiler 12 in position upright on a flat surface inside the cabinet with the connections to the top 3 Take the G1 4 female nut 20 B...

Страница 9: ...scharging from the vent pipe Important note If water does not start to discharge from the vent pipe into the cup after 20 minutes switch off the power operate the boiling water function on the tap to...

Страница 10: ...ng the Omni tap The body of the tap is clearly marked to show the 2 functions Boiling Filtered water Remove the red safety clip 3 Depress the boiling water lever to release the safety lock and rotate...

Страница 11: ...rew the sump by hand until it separates from the head of the filter 5 If the old cartridge does not automatically fall free press down on the top mount of the cartridge to release it Remove the old ca...

Страница 12: ...dicates that the filter cartridge is clogged with contaminants and needs replacing You can check by operating the filtered water with no cartridge in the filter housing The flow of filtered boiling wa...

Страница 13: ...ication it should be replaced Foam or a film is forming on the surface of hot drinks This is caused by a combination of the agitation of the boiling water creating millions of tiny air bubbles the ph...

Страница 14: ...e have your receipt to hand so that we can record your date of purchase The company reserves the right to alter change or modify product specifications without prior notice Guarantee This Franke produ...

Страница 15: ...electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise b...

Страница 16: ...M22 5WB Phone 44 0 161 436 6280 Email info uk franke com www franke co uk After Sales Service FilterFlow Old Winery Business Park Chapel Street Cawston Norfolk NR10 4FE Phone 44 0 1603 875 468 Email...