background image

1

0316 

 KEPACSL-EBF_036865-066

A. INSPECTION

Inspect the water cooler, water fountain and cartons for evidence of rough handling and concealed damage. Damage claims should be 

filed with the carrier.

B.  TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE

1.  

NOTE:

 Provincial and local plumbing code may prohibit the use of saddle tapping valves for water line connection in some applica-

tions. All connections must conform to applicable plumbing codes.

2.  The KEP8ACSL is composed of a water cooler and a water fountain. The water cooler contains the refrigeration system and is 

always mounted on the right side. This unit can be configured with the water cooler high or low. Refer to the proper roughing in 

drawing for location of plumbing and electrical service.

3.  FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT.

4.   Install wall hangers as shown on the desired roughing in drawing. Wall hangers are shipped fastened to the backs of the unit. Units 

with factory installed filters have additional instructions on a label inside of the access panel. Read these before installing the unit.

5.  

This unit has been factory assembled for right side high installation. To convert for right side low installation:

a)   Remove the patch plate from the left side panel of the water cooler and install on the right side panel of the water fountain re-

using the two mounting screws. The two bottom screws from each side panel may be temporarily removed to improve access.

b)   Remove the screws holding the waste drain tubes from the cooler tops. The shorter drain will be used on the water cooler and 

the longer drain will be used on the water fountain. Make sure that the waste drain gaskets are properly installed.

6.   Mount the water cooler on the right hanger.
7.   Straighten the inlet “Water In” tube in the water fountain. Mount the water fountain on left side hanger while routing the “Water 

In” tube through the access hole to the water cooler. Remove the plug from the “Drain/Remote Cold Water” connection and insert 

the “Water In” tube.

8.  

All provided waste drain parts for field installation are packed in the water fountain. Assemble the drain per the appro-

priate roughing in drawing. The short leg of the crossover piece will be on the water cooler side. When the unit has an 

internal waste trap, the trap should be wrapped with insulating tape to prevent sweating. The use of the 1 3/4" knockout 

for a waste line is not recommended because of a potential conflict with ADA* toe space requirements. Check with your 

local building code inspector for approval.

9.  Install a shut off valve in water supply line. Remove the strainer from the cooler “Water Supply” tube. Solder 3/8" inlet tube exten-

sion (furnished) with lead free solder to “Water Supply” tube and insert the strainer in open end of extension. Connect extension 

to shut off valve to allow access to strainer for service, this connection should not be a solder or flare joint. To ease removal of the 

strainer, a sheet metal screw may be lightly threaded into the open end.

10. Rotate the fan blade by hand to see that it is free of obstructions.
11. Check the available power supply against the water cooler data plate to assure correct electrical service. Plug power supply cord 

into wall outlet. The rear most 1 3/8" diameter knockout in the frame bottom is for an externally located electrical supply. Make 

sure the knockout hole edge is smooth and free of any burrs. Use of a Heyco busing #2184 in the knocked out hole is recom-

mended in order to prevent damage to the service cord and to close up excess opening around the cord. Route the cord so it 

does not interfere with ADA* space requirements.

12. To fill the cold water tank on the water cooler, open the water supply line shut-off and push any one of the front push-button to 

allow water to flow to the bubbler. On The EE model, actuate the solenoid by holding one hand approximately 3 inches from the 

infrared sensor. Run water until stream is free of bubbles.

13. To adjust bubbler stream:

a)  All pushbutton models are equipped with a cartridge regulator. The KEP8ACSL and KEPACSL have a slot in the shelf below the 

push-button. Insert a screwdriver in this slot to adjust  regulator. Turn adjustment clockwise to increase stream height. To ac-

cess the KEPV8ACSL adjustment, remove the bezel and button from the front of the cooler.

DRINKING FOUNTAIN INSTALLATION

For All Universal Split Level KEP( )ACSL-EBF Series Drinking Fountains 

with Electronic Bottle Filler 

Содержание KEP ACSL-EBF Series

Страница 1: ...the appro priate roughing in drawing The short leg of the crossover piece will be on the water cooler side When the unit has an internal waste trap the trap should be wrapped with insulating tape to...

Страница 2: ...i e ceramic tile across from the sensor may cause false actuation no matter what the sensor adjustment is for distance Therefore do not install the unit in such an area or dull the surface of the wall...

Страница 3: ...ES 4 PLCS ELECTRONIC EYE MODELS ONLY PUSH PAD WATER COOLER AND FOUNTAIN KEPV8ACSL PUSH BUTTON OPTIONAL GLASSFILLER LOCATION WATER COOLER 1 1 4 O D TAILPIECE AIR FLOW 1 1 4 IPS WASTE OPTIMUM LOCATION S...

Страница 4: ...AILPIECE 3 8 O D WATER INLET WITH STRAINER 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1 32 941 1 2 13 2 PLCS 3 5 16 84 12 3 4 324 2 PLCS 6 3 8 162 2 PLCS AIR FLOW ELECTRONIC EYE MODELS ONLY 1 4 8 MOU...

Страница 5: ...BARRIER FREE HEIGHT INSTALLATION SHOWN REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30 760 BY 48 1220 AD...

Страница 6: ...nstalled onto a refrigerated drinking fountain chilled water can be dispensed through the Bottle Filler Otherwise room temperature water will be dispensed The Bottle Filler is shipped partially assemb...

Страница 7: ...7 8 9 10 11 NOT PRE DRILLED BOTTLE FILLER KIT If the unit is not pre drilled or you purchased a BOTTLE FILLER retrofit KIT go to next PAGE 8 STEP 1 PRE DRILLED If your unit was purchased pre drilled...

Страница 8: ...nits are single units made since December of 2009 Refer to the schematic below to identify the system that you have Mark hole location Template Remove top from cooler by removing six 15 torx head scre...

Страница 9: ...1 8 po 5 4cm FROM BACK Mark this center point on the top Remove the top from the cooler Then drill a 7 8 2 2cm hole through the top at the marked centre point ALIGN THIS EDGE WITH LEFT EDGE OF COOLER...

Страница 10: ...TEE fitting supplied will need to connect be tween the cooling tank and valve Figure 3 STEP 3 Disconnect tubing from the elbow on the valve Figure 4 STEP 4 Using the 30 piece of tubing provided cut 6...

Страница 11: ...sser le tuyau dans le dessus et fixer ce dernier au refroidisseur Figure 10 Figure 7 TAPE 6 STEP 6 Feed tubing up through the top and attach the top to the cooler Figure 7 SECTION 2 CONNECTING THE WAT...

Страница 12: ...2 Make sure to pull the plastic tubing up through the hole in the frame Use mounting slots that will provide the proper securing location Bottle filler cabinet Groove in the gasket Figure14 STEP 4 Sli...

Страница 13: ...iller power supply to female terminals on power cord Make sure male tab is seated inside metal contacts of female terminal STEP 9 Plug in bottle filler cord The program should be set up specific for t...

Страница 14: ...TERED UNIT press and hold button for about 3 seconds Press button for an instant to advance to next menu item 5 If you wish to reset filter life counter or bottle counter press and hold button for 3 s...

Страница 15: ...15 0316 KEPACSL EBF_036865 066 1 2 3 26 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22 22 23 24 25 25 22 4 27 28 29 30 31 32 33 EXPLODED PARTS BREAKDOWN ELECTRONIC SPORTS BOTTLE FILLER...

Страница 16: ...8706 036 Washer spacer gasket non metallic 18 026670 007 Screw hex heavy duty machine 19 028481 101 Fitting PP union elbow white 20 036209 001 Fill tube assembly 21 026642 003 Bracket fill tube suppor...

Страница 17: ...Drinking Water Temperature Specifications subject to change without notice 115 VAC 10 1 PH 60 Hertz 35 1 4 W 18 5 8 D 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F SPECIFICATION...

Страница 18: ...8 flat blade screwdriver into the slotted hole as shown The screwdriver will engage the stream height adjuster in the cartridge plunger Turn clockwise to increase stream height or counter clockwise t...

Страница 19: ...ld control 027040 039 027040 039 Not applicable 23 Relay 036056 003 036056 003 Not applicable 24 Overload 036055 003 036055 003 Not applicable 25 Start capacitor 60 MFD 027956 008 027956 008 Not appli...

Страница 20: ...Kindred Road Midland ON L4R 4K9 Tel 1 855 446 5663 Fax 1 866 227 3050 www franke commercial com 0316 KEPACSL EBF_036865 066 WIRING DIAGRAM Single KEP __ series Split Level KEP __ series WIRING DIAGRAM...

Отзывы: