20. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
21. Replacement Parts
Fault
Cause
Remedy
Water does not flow
– Battery dead (red LED lights up)
➯
Replace it
– Water-flow volume regulator closed
➯
Open it
– Grit filters are clogged with dirt
➯
Clean them
– Cleaning clip in front of the fitting
➯
Remove
– Electronic system in sleep mode
➯
Shine bright light
in front of the
sensor
– Solenoid valve faulty
➯
Replace it
Water flows
continuously
– Solenoid valve faulty
➯
Replace it
Water flow too weak
– Corner valves not fully opened
➯
Open it
– Grit filters are clogged with dirt
➯
Clean them
– Aerator calcified
➯
Clean them
– Supply pressure too low
➯
Check it
Water is too hot
– Cold water is turned off
➯
Open it
– Filter in cold-water part is dirty
➯
Replace it
– Non-return valve faulty
➯
Replace it
Water is too cold
– Hot water is turned off
➯
Open it
– Filter in hot-water part is dirty
➯
Replace it
– Non-return valve faulty
➯
Replace it
Designation
Order No.
1 Aerator with flow-
regulator (VPE 10 St.) . . . . . . . . . 81-013-03.057
2 Lithium battery 6 V type CRP2 . . . 85-032-02.830
3 Solenoid valve cartridge
with grit filter . . . . . . . . . . . . . . . . 85-100-20.578
4 Cleaning clip . . . . . . . . . . . . . . . . 85-032-02.831
5 Maintenance kit comprising:
Non-return valve
Grit filters. . . . . . . . . . . . . . . . . 81-500-03.028
6 Hose . . . . . . . . . . . . . . . . . . . . . . 82-024-03.123
Designation
Order No.
7 Maintenance kit comprising:
O-rings
Screws
Grit filters . . . . . . . . . . . . . . . . . 85-500-03.012
8 Mixing lever with screw . . . . . . . . . 85-100-20.198
Accessories
Order No.
9 Remote control . . . . . . . . . . . . . . . 5207 10 00
10 Base for installation on
stainless steel washbasin . . . . 85-500-02.021
[email protected] - www.hygiene-shop.eu