Technical Specifications
7. Assembly Instructions
Warning!
• To be installed by qualified electrician only.
• Disconnect voltage.
• Secure against reclosing.
• Check absence of voltage.
• Earth and short circuit.
• Cover neighbouring live parts or make them inaccessible.
Failure to observe can mean risk of death or material damage, e. g. from electric shock
or fire.
7.1
Strip off 8 mm (max. 9 mm) of the electric lead .
7.2
Using a screwdriver, press into the opening (a).
• The spring-clamp terminal (b) opens up.
Nominal voltage:
230–240 V AC, +10 % / -15 %
Rate:
50–60 Hz
Internal consumption:
max. 6 VA
Switch output:
independent of phase (voltage pass through
zero)
Contact:
Changeover contact element
Contact material:
AgSnO
2
Switching capacity, max.:
16 A, 250 V AC, cos ? = 1;
10 A, 250 V AC, cos ? = 0,6
Switching capacity, min.:
10 mA / 230 V AC;
100 mA / 24 V AC/DC
Contact rating:
5 A per contact
Permissible ambient
temperature:
–30 °C to +50 °C
Protection class:
II according to EN 60730–1 when installed as
intended
Type of protection:
IP 20 according to EN 60529
Degree of contamination:
2
Reserve power:
10 years at 20 °C
The reserve power is less when a memory card
is in use (with battery operation).