background image

                                                                                                 G Max Operation and Maintenance Manual 

 

 

1.11 Transport and handling  

 

 

 

The machine is properly packed in sturdy cardboard boxes. 
Be careful when opening the packaging to prevent damaging the unit. Check the integrity of 
the machine making sure that there are no visibly damaged parts.  
Do  not  dispose  of  the  packaging  elements  in  the  environment:  they  must  be  stored  in 
appropriate collection points. 
The 

G Max 

heater can  be  lifted  and  suspended  using  the  appropriate  fixing  and  handling 

brackets. 
 

ATTENTION!

 

Before moving the unit: 

 

a. 

stop the machine, 

b. 

switch off the power supply, 

c. 

cut the gas supply, 

d. 

wait for the heater to cool down. 

 

Use  suitable  lifting  gear  to  move  the  machine.  The  weight  is  indicated  on  the  nameplate  and  in  the 
manual  at  par.  5.1  "Technical  data".  Carry  out  the  operations  with  caution,  using  the  appropriate 
personal  protective  equipment,  making  sure  that  the  machine  is  not  subject  to  shocks  or  falls,  and 
positioning the lifting belts correctly. 

 

1.12 Warranty  

 

This  product is guaranteed for 12 months from the date of manufacture for all faults attributable to a 
proven manufacturing or material defect. The warranty does not cover all parts damaged by transport, 
bad  or  incorrect  maintenance,  neglect,  inability  to  use,  improper  use,  tampering  by  unauthorized 
personnel  and  in  any  case  from  causes  not  dependent  on  Franco  s.r.l.  -  Cervasca  (CN).  During  the 
warranty period, Franco s.r.l. undertakes to provide free of charge those parts that may be defective at 
the origin. 
Any repair work must be carried out by a qualified technician authorized by Franco s.r.l. 

 

1.13 Manufacturer's identification data  

 

Manufacturer

 

FRANCO s.r.l. 

 

Legal and administrative headquarters

 

VIA NAZIONALE, 80 - 12010 CERVASCA (CN) - ITALY 

 

Contact

 

Tel.: 

(0039) 0171 - 61.16.63 

Email: 

[email protected] 

Web: 

www.francosrl.com 

 

1.14 Declarations  

 

The  machine  is  manufactured  in  compliance  with  the  relevant  European  Directives  applicable  at  the 
time of its placing on the market. 
The machine is not included among those listed in All. IV of Directive 2006/42/EC. 
 

 
 
 

Содержание G Max

Страница 1: ...HEATER T R A N S L AT I O N O F O R I G I N A L I N S T R U C T I O N S E N G L I S H C O U N T R Y O F D E S T I N AT I O N Read this manual carefully before installing and operating the unit Rev 00...

Страница 2: ...1 12 Warranty 9 1 13 Manufacturer s identification data 9 1 14 Declarations 9 1 15 Declaration of conformity 10 2 INSTALLATION 11 2 1 Preliminary operations 11 2 2 Positioning 11 2 3 Fire prevention...

Страница 3: ...the device with wet or damp hands Do not pull the power cords or expose them to a risk of shearing Do not leave the device directly exposed to the weather rain sun etc In case of failure or malfunctio...

Страница 4: ...ontact the manufacturer support francosrl com for support 1 5 Target readers This manual is intended for the installer the operator and qualified personnel authorised to service the machine OPERATOR m...

Страница 5: ...ompliance with the laws in force in the Country of destination of the machine Mechanical maintenance technician qualified technician able to operate the machine under normal conditions to make it work...

Страница 6: ...circle impose a PROHIBITION OBBLIGATION Pictogram Description Dangerous electrical voltage General hazard Hot surfaces danger Do not remove safety guards and devices Do not clean oil grease repair or...

Страница 7: ...ignition sequence checks the presence of flame during operation and locks the machine out in case of anomalies Safety thermostat with manual reset protects the appliance from overheating by switching...

Страница 8: ...trical panel Fig 1 3 Fan Safety thermostat Sensing ignition electrodes Nozzle Handling brackets Burner reset button Room thermostat socket Pipe connection power supply gas M Schuko plug CEE 7 4 Thermo...

Страница 9: ...lls and positioning the lifting belts correctly 1 12 Warranty This product is guaranteed for 12 months from the date of manufacture for all faults attributable to a proven manufacturing or material de...

Страница 10: ...following European Directives 2006 42 EC Machinery Directive EU 2016 426 Gas Appliances Regulation Cert n CE51CS4822 issued by IMQ 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibi...

Страница 11: ...a distance from the wall on a suitable support structure The guidelines provided are purely indicative the optimal position of the air heater in relation to the room to be heated must be chosen by the...

Страница 12: ...g inlet and outlet ducts Fig 2 2 2 Wall installation with air recirculation or external suction n 20 self tapping screws hexagonal head flanged 4 2x13 Bracket Washer Grower Washer Screw M8 Bracket Fla...

Страница 13: ...sent The following table shows the theoretical values of the fresh air flow rate to be introduced into the environment according to the installed thermal power in order to maintain a CO2 concentration...

Страница 14: ...if necessary a pressure regulator parts not supplied Only use an approved flexible hose with a maximum length of 2 m for the connection and make sure it is free of restrictions Do not use metal tubin...

Страница 15: ...in the technical data tables for the type of gas used Start the heater by setting the room thermostat to the desired temperature or in the case of manual operation by powering up the appliance via an...

Страница 16: ...To start the heater set the room thermostat to the desired temperature or with manual operation power up the appliance by turning the switch provided in the electrical system to ON During operation In...

Страница 17: ...nal use G Max heaters are mainly intended for seasonal use At the end of the winter season or in general if the appliance is not used for long periods Disconnect the appliance from mains and close the...

Страница 18: ...iodically check the tightness of screws and bolts especially in the presence of unusual noises and vibrations 4 2 Cleaning and replacing the nozzle Open the inspection door unscrew the nozzle from the...

Страница 19: ...h 3000 Gas consumption 1013mbar 15 C G20 methane G30 G31 propane butane m3 h kg h 6 67 5 07 Gas pressure G20 methane G30 G31 propane butane mbar mbar 20 28 30 37 Nozzle diameter G20 methane G30 G31 p...

Страница 20: ...d Maintenance Manual 20 5 2 Spare parts list Use only original spare parts Orders should be placed specifying at least the following Appliance model Mfg year Spare part number Quantity Shipping addres...

Страница 21: ...IT W FIXING SCREWS 8 4202050 1 COMPLETE BURNER 8a 4202062 1 BURNER FIXING KIT 9 7302003 1 IGNITION SENSING ELECTRODES 9a 1257500 1 FIXING KIT FOR IGNITION SENSING ELECTRODES 10 8102000 1 GAS PIPE 11 4...

Страница 22: ...HER 4 4202055 1 COMPLETE GAS VALVE 5 7302100 1 FLAME CONTROL BOARD 6 1454215 1 RELAY 7 7301100 1 FUSE HOLDER 8 7304002 1 FUSE 5X20 STD 6 3A 9 4202056 1 TERMINAL BOARD 9a 4205000 1 WIRING KIT 10 700400...

Страница 23: ...5 1 Technical data Make sure that all electrical connections on the terminal block and on the components are firmly secured that the box cover is well closed and that the closing screws are tightened...

Страница 24: ...or and fan can rotate freely Check voltage at motor terminals Replace if necessary Previous trip of an external thermal motor protector if applicable Check that the motor rotates freely inspect the ai...

Страница 25: ...d outlet Insufficient or excessive installed heating power for the room to be heated Review plant dimensioning The heater locks out or stops during operation Power failure Check the electrical system...

Страница 26: ...ion and Maintenance Manual 26 Faulty flame control device safety thermostat or flow switch tripping even if there is no problem Check operation of components clean contacts check connections replace i...

Страница 27: ...G Max Operation and Maintenance Manual 27...

Страница 28: ...al 28 FRANCO s r l headquarters and factory Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 Fax 39 0171 612337 www francosrl com info francosrl com For any question you are welcome to...