1340505 VICKY
Page 4
CONNECTION TO THE CHIMNEY FLUE
The flue should be connected to the appliance and must comply with all local and
national regulations. They especially depend on the type of flue, its thermal
resistance and its temperature class.
Example of a connection to the chimney flue.
General connection rules for a flue using the rear exit option.
CHANGING FLUE CONNECTION
•
Remove the flue spigot from the top of the stove.
•
Remove the rear heat shield and the rear flue blanking plate.
•
Fit the blanking plate and any gasket to the top of the stove.
•
Fit the flue spigot and any gasket to the rear of the stove.
•
The round knockout panel on the rear heat shield should now be removed.
•
Fit the rear heat shield to the stove.
•
If using the rear flue option we recommend that a physical retention method is used.
FREE AIR DUCT
The product is fitted with a with an air inlet spigot that will accept a pipe of diameter 100mm externally, Part No. FBA004.
The air duct fitted must be of minimum diameter 100mm, non-combustible and ducted to the outside in a manner that will not affect
the performance of the stove.
No sharp bends and a maximum duct length of 10 metres is permissible. Where the duct terminates on an external wall, ensure that
there is no risk of blockage with leaves or accidental placement of items, ensure there is no risk of ingress of moisture or access for
rodents.
Fresh Air Kit: FBA004