5 - Electrical Installation
For safety purposes, only competent personnel should perform the electrical installation. All
equipment should be installed to current Electrical Regulations and Standards.
In order to obtain the maximum light output from the searchlight, it is essential that the full
operating voltage of the lamp fitted be applied to the lampholder contacts.
Method of Electrical Connection
1)
Disconnect the supply before working on the electrical system;
2)
The searchlight must be connected to a fused electrical supply, using suitably sized cable;
3)
If the searchlight is located a considerable distance from the supply, provision must be
made in the cable size in order to overcome the voltage drop.
The PSU should NOT be positioned no more then 5 meters away from the searchlight
.
The following table below indicates the maximum length of cable to be used for the AC
supply cable, from the supply to the searchlight:
Searchlight
115v 1Kw
240v 1Kw
Cable Size (mm²) Distance Max Distance Max
1.5
17 MTRS
75 MTRS
2.5
28 MTRS
123 MTRS
4
44 MTRS
195 MTRS
6
68 MTRS
304 MTRS
10
115 MTRS
509 MTRS
4)
Whenever possible cable terminations should be made below deck and with approved
terminal devices;
5)
If a spare auxiliary fuse or circuit breaker is not available, one of the correct type and rating
should be fitted and connected to a positive supply. It is advisable to locate a bus bar or
main connection and avoid any direct connection to the supply: