Transport platform
SEP Serie
SEP u
ser’s manual Page 70 of 89
Doc no. RD-7243-MA-001-02
9.3. Monthly maintenance
•
In addition to the daily and weekly inspection elements, consider the following elements:
•
Check that
every bolt
of the mast, individual mast sections and end of mast section, of
the base, of the travel en detectors, of the floor runners, of the centrifugal emergency
brake, of the mast attachments and building anchors are tightened and safe. Tighten
bolts according to the tightening torque guidelines as needed.
•
Inspect alignment of the rack.
•
Check the wear of the pinions, planetary gears and on the segments of the rack. Check
with the 0,55" (14 mm) rectified stem. Replace parts as needed.
•
Lubricate the centrifugal emergency brake through the four (4) lubrication points.
9.4. Quarterly maintenance
•
Perform the
drop test
by following the present manual instructions. This test is required
periodically by safecty standards and it is possible that effective local laws and
regulations require that this test be performed more frequently.
∞
S
EE SECTION
ON PAGE
•
Inspect the condition of all data plates, stickers and warnings present on the platform. All
data plates and stickers must be legible and in good condition. Replace as needed.
∞
S
EE SECTION
ON PAGE
•
Check the level of the lubricant tank (
tank is optional
).
o
The necessary quantity of lubricant necessary for 120h of normal operation is 1,2L.
o
Fill the lubricant tank before it empties.
To fill the tank, connect the lubricating pistol to the filling connector. Fill the tank until
the lubricant reaches the
MAX
level.
WARNING!
Lubricants with solid components are not adapted to this pump.
Figure 42
– Safety device greasing points
.
Mandatory lubrication
points of the
emergency brake.