Location
VISAIR CABINETS
-
INSTALLATION
Operating
Environment
The cabinet is designed to maintain products at a temperature above 65
C.
The heating system is designed to maintain this temperature, providing the
cabinet is not located in a draughty location.
Do not place electric fans close to the open front of the cabinet.
Place
A minimum space of 50mm should be left behind the cabinet, to allow air to
circulate through the vents and fan.
Power Supply
VISAIR CABINETS
-
INSTALLATION
Power Supply
Connection
The VH12 and VH14 cabinets have a three-core
mains lead, with 15A plug. If damaged, the lead
must only be replaced by a qualified service
person.
The VH24 cabinet has terminals for connecting
the incoming mains supply phase, neutral and
earth conductors.
The terminals are mounted at the back of the
left control gear chassis.
Before connecting to the power supply, check
that the local supply is correct to that shown on
the rating label, located behind the removable
front panel.
Ensure that the cables used are adequately
rated for the load current, and that there is
enough slack cable to enable the chassis to be
withdrawn for servicing.
Electrical
Isolation
An accessible means of isolation must be provided in the electrical supply to the
cabinet.
Earthing
THIS APPLIANCE MUST BE EARTHED/GROUNDED
The cabinet should be earthed via the earth lead in the mains cable.
In addition, an equipotential earth bonding terminal is provided, to allow the
cabinet to be bonded to a building surge earth or adjacent equipment.
Содержание Visair IN-VH06
Страница 1: ...Open Front Hot Food Display Cabinets...
Страница 32: ...Part No 24895 Rev Y March 2018 32 Visair Heated Cabinets IN VH09...
Страница 34: ...Part No 24895 Rev Y March 2018 34 Visair Heated Cabinets IN VH12 A002...
Страница 35: ...IN VH06 VH09 VH12 VH18 and VH24 35 Future Products Group IN VH12 A004...
Страница 36: ...Part No 24895 Rev Y March 2018 36 Visair Heated Cabinets IN VH12 A008...
Страница 37: ...IN VH06 VH09 VH12 VH18 and VH24 37 Future Products Group IN VH12 A006...
Страница 38: ...Part No 24895 Rev Y March 2018 38 Visair Heated Cabinets IN VH18...
Страница 40: ...Part No 24895 Rev Y March 2018...