IN 5C08/12/15/18/24.
- 37 -
© Future Products Group
Controller Setting
REFRIGERATED CABINETS
-
SPECIFICATIONS
Dixell XR40CX Settings
Parameter
Integral
Condenser
Models
Remote
Condenser
Models
Integral
Controlled
Ambient
Remote
Controlled
Ambient
Units/Range
Set Point
Set
2
2
16
16
degC
Differential
Hy
2
2
2
2
degC
Anti Short Cycle Delay
AC
0
0
0
0
Min
Comp On Time - Faulty Probe
C0n
4
4
4
4
Min
Comp Off Time - Faulty Probe
C0F
6
6
6
6
Min
Defrost Terminate Temp
dtE
3
3
3
3
degC
Interval Between Defrosts
idF
4
4
4
4
Hrs
Display During Defrost
dFd
DEF
DEF
DEF
DEF
rt, it, Set, DEF
Maximum Temperature Alarm
ALU
12
12
110
110
degC
Differential For Temp Alarm
AFH
8
8
1
1
degC
Temperature Alarm Delay
Ald
60
60
15
15
Min
Probe For High Temp Alarm
AP2
nP
nP
nP
nP
nP, P1, P2, P3, P4
Digital input polarity
i1P
oP
cL
oP
cL
cL, oP
Digital input configuration
i1F
PAL
EAL
PAL
EAL
EAL, bAL, PAL,
dor, dEF, AUS, Htr,
ES
Digital input alarm delay
did
0
5
0
5
Min
Activations of pressure switch
Nps
1
15
1
15
0-15
Parameters shown thus are Dixell default settings