Part No. 26126 Rev. P September 2019
- 32 -
5000 Series Open Front Cabinets
Controller Setting
REFRIGERATED CABINETS
-
SPECIFICATIONS
Dixell XR40CX Settings
Parameter
IN-5C08
Integral
IN-5C08
Remote
IN-5C12
Integral
IN-5C12
Remote
Units / Range
Set Point
Set
-6
-6
-6
-6
degC
Differential
Hy
5
5
5
5
degC
Third Probe Presence
P3P
Y
n
Y
n
n, Y
Fourth Probe Presence
P4P
Y
Y
Y
Y
n, Y
Fourth Probe Calibration
O4
-2
-2
-2
-2
degC
Anti Short Cycle Delay
AC
0
0
0
0
Min
Comp On Time - Faulty
Probe
C0n
4
4
4
4
Min
Comp Off Time - Faulty
Probe
C0F
6
6
6
6
Min
Probe Displayed
Lod
P4
P4
P4
P4
P1, P2, P3, P4
Defrost Terminate Temp
dtE
4
4
4
4
degC
Interval Between
Defrosts
IdF
2
2
2
2
Hrs
Display During Defrost
dFd
DEF
DEF
DEF
DEF
rt, it, Set, DEF
Probe For High Discharge
Temp Alarm
AP2
P3
nP
P3
nP
nP, P1, P2, P3, P4
High Discharge Temp
Alarm Set Point
AU2
120
110
120
110
degC
High Discharge Temp
Alarm Diff
AH2
25
5
25
5
degC
High Discharge Temp
Alarm Delay
Ad2
0
15
0
15
Min
High Discharge Temp
Alarm Delay At Start
dA2
0
1,3
0
1,3
Min
Comp Off For High
Discharge Temp Alarm
AC2
Y
n
Y
n
n, Y
Содержание IN-5C08-OF
Страница 1: ...Refrigerated Open front Cabinets Curved and Square Formats...
Страница 39: ...IN 5C08 12 OF 39 Future Products Group IN 5C08 5C12 OF SQ...
Страница 40: ...Part No 26126 Rev A November 2014 40 5000 Series Open Front Cabinets IN 5C12 OF...
Страница 41: ...IN 5C08 12 OF 41 Future Products Group...
Страница 42: ...Part No 26126 Rev A November 2014 42 5000 Series Open Front Cabinets...
Страница 43: ...IN 5C08 12 OF 43 Future Products Group...