IN 4C 08/12/15/18
- 17 -
© Future Products Group
Routines
REFRIGERATED CABINETS
-
CLEANING
Schedules
To maintain optimum performance, cleaning schedules must be regular and
thorough.
Warning
Failure to carry out routine cleaning/servicing schedules will void the
warranty on the refrigeration equipment.
Condenser
Radiator
For efficient refrigeration performance,
the condenser radiator must be kept
clean. Failure to do this will lead to a
build-up of dust, and restricted airflow
will prevent the unit from working
properly. The compressor may overheat
and the cabinet temperature may rise.
Regular vacuuming will prevent a build-
up of dust and fluff, however, three
monthly service checks, which include
cleaning of the condenser using C0
2
by a
refrigeration engineer, are mandatory.
Remove the louvered panel to access the radiator. Be very careful not to bend
or damage the soft aluminium fins when vacuuming the radiator. If the fins are
flattened, airflow will be restricted and overheating will result.
Condensate
The condensate container should be checked
each time the cabinet is cleaned.
The quantity of water will depend on the relative
humidity and cabinet contents. Natural
evaporation can be sufficient to keep the
container empty, but if water has accumulated, it
should be removed and emptied regularly.
If preferred, particularly in high humidity
situations, the condensate can be plumbed to a
drain.
Inspection
As part of the cleaning routine, the controls, mechanical parts and electrical
wiring should be inspected for damage, deterioration or need of adjustment.
Fault
Correction
If any small faults are found, have them attended to promptly by a competent
serviceman. Don’t wait until they cause a complete breakdown.