Part No. 26984 Rev. C May 2018
- 10 -
Refrigerated Milk Drawer
Preparation
cont.
REFRIGERATED CABINETS
-
OPERATION
Power Supply
Ensure that power is connected to the cabinet.
Close the
Drawer
It is important to keep the drawer closed.
If the drawer is not fully closed, an even
temperature will not be maintained within
the cabinet.
Use the front flap to access product.
Opening it has little effect on product
temperature, but it is recommended to
close it after removing product.
Turn on Main
Switch
Turn on the main power switch, as shown earlier. The refrigeration condenser,
and the evaporator and drawer fans will run.
The temperature controller is pre-set to maintain the drawer temperatures at 2
- 4
C. It should not need adjustment.
Operating Routines
REFRIGERATED CABINETS
-
OPERATION
After Hours
Ideally, cabinets should not be turned off after hours.
If the cabinet is turned off, move the products to cool storage, and allow the
cabinet to run for about half an hour before replacing the pre-chilled products.
Cleaning
It is recommended to clean the cabinet at the end of the working day, since it
needs to be shut down for this.
Once the cleaning is finished, turn the cabinet on again and let it cool down
before re-loading chilled product.
De-frost Cycle
The cabinet will de-frost automatically every four hours, starting from when the
cabinet is first turned on. If defrost is wanted at a particular time, you must turn
on the cabinet four hours before the first defrost required.
The cabinet should NOT be temperature tested within ½ hour of a de-frost
programme being completed.
If you suspect that the defrost system is not working properly, have it checked
by a qualified service person.
Operators must not attempt to adjust the refrigeration controller.