observe the camera status indicator light, if there is a non
flashing indicator light corresponding to the camera, the
data cannot be recorded, By restarting the camera and
waiting for the self-test to be completed, the observation
indicator light will be on normally to avoid data loss. 2. Due
to the insufficient setting of the external control signal
duration, the external signal cannot support the complete
exposure of all cameras. The solution to the problem can
adjust the duration of the external control signal to the
standard time specified in the manual, which can generally
ensure the complete triggering of all movements. 3. Due to
insufficient external power supply, there is not enough
power to drive the synchronous exposure of five movements.
Generally, when the voltage of the aircraft is too low during
flight, the power supply of the tilt camera is insufficient due
to the large part of the power of the aircraft's main power.
Specifications
Machine specification
Number of shots
5
Tilt angle
0°X1 & 45°X4
Dimensions
148*167*86mm
Weight
580g