I. Introduction

Fountain Tech pumps are carefully inspected and tested to insure 
both safety and operating performance.  However, failure to 
follow the instructions and warnings in this manual may result 
in pump damage and/or serious injury. Please read and save this 
manual for future reference. 

II. Performance

° A clogged or dirty intake screen will greatly reduce perfor-
mance. If the pump is used on a dirty surface, raise it slightly to 
reduce the amount of debris contacting the Intake.

Fountain TECH FT-50 Pump

WARNING

° This pump is supplied with grounding connector and a 
grounding type attachment plug. To reduce the risk of electric 
shock, connect only to a properly grounded outlet.
° Do not remove the grounding pin from the plug.
° Do not connect any voltage other than that shown on the 
pump.

° Do not pump  ammable liquids.
° The National Electric Code requires that a Ground Fault 

Circuit Interrupter (GFCI) be used in the branch circuit supply-

ing fountain pumps and other pump equipment. See your local 

electrical supplies dealer for this device.
° To reduce the risk of electrical shock, use only on portable 
self contained fountains no larger than 5 feet in any dimension.
° Do not use with water above 86° F.

Failure to observe any of these safety precautions may result in 
pump damage and/or serious injury. 

Gallons Per Hour

CAUTION

ALWAYS DISCONNECT THE PUMP FROM THE ELECTRI

-

CAL OUTLET BEFORE HANDLING.

DO NOT LET THE PUMP RUN DRY.
DO NOT LIFT THE PUMP BY THE POWER CORD.
DO NOT PUMP HEATED LIQUIDS.
OPERATE IN FRESH WATER ONLY.
OPERATE PUMP COMPLETELY SUBMERGED FOR PROPER 

COOLING.

° If less  ow is desired, adjust the  ow control lever on the side of 
the pump or restrict the discharge  ow.

° Do not allow the pump to run when not submerged. Doing so may 

damage the pump. Always submerge the pump  rst and then plug in 

the electrical cord.

° It is common for there to be air in the pump and tube when  rst 
plugged in. Pull the electrical cord out and re-insert it until the  uid 
begins to  ow. 

° This pump comes with multiple connector tubes. If desired, re-
move and insert other size.

III. Maintainance

To clean the pump, remove the front plate and the impeller. Use a 
small brush or stream of water to remove any debris. CAUTION: 
The pump shaft can not be removed. 

IF THE PUMP FAILS TO 

OPERATE, CHECK THE FOLLOWING:

° Check the circuit breaker and try another outlet to insure the pump 
is getting power. NOTE: Always disconnect the pump from the 
electrical outlet before handling the pump.
° Check the pump discharge and tubing for kinks and obstructions. 

Algae buildup can be  ushed with a garden hose.

° Check the inlet screen to insure it is not clogged with debris.
° Remove the pump inlet to access the impeller area. Turn the rotor 
assembly to insure that it is not broken or jammed.

° Monthly maintainance will add to your pump s life.

NOTE:

 Insure that the electrical cord loops below the electrical 

outlet to form a “Drip Loop”. This will prevent water from running 
down the cord into the electrical outlet.

FT-50.indd   1

1/4/2008   6:02:06 PM

Fountain TECH FT-40 PUMP

FT-40 FLOW CHART