Layer 3 Upgrade Procedures
December 2008
© 2008 Foundry Networks, Inc.
A - 9
FI12GM-6 and SX-FI12GM2-6)
Installation Overview
You need a Phillips-head screwdriver and an ESD wrist strap to perform this procedure. You also need a static-
free work area.
To perform the upgrade:
1.
If your Foundry device does not have redundant management modules, power down the chassis and remove
the power cables from the chassis power supplies.
WARNING:
Disconnect the power cord from all power sources to completely remove power from the device.
2.
Remove the management module from the chassis and place it on a static-free work area.
3.
Insert the Dual Inline Package (DIP) key provided in this upgrade kit into the DIP socket on the motherboard.
The location is labeled as follows:
•
U63
on the SX 800 and SX 1600 management modules
•
U53
on the SuperX management modules
CAUTION:
Make sure you insert the DIP key so that lead pin 1 goes into the correct hole as shown in Figure
A.4, Figure A.5, Figure A.6, Figure A.7, and Figure A.8, depending on the management module type. If you
accidentally insert the DIP key backwards, the device will not work and may be damaged when you power it
on.
4.
Replace the management module.
Re
a
r
Port Connector
s
CAUTION: PIN 1
MU
S
T GO HERE
!
If you accidentally insert
the upgrade DIP backwards,
the device will not work and
may be damaged when you
power it on.
DIP key
for
u
pgr
a
de
Pin 1
U5
3
Содержание FastIron SuperX
Страница 139: ...Maintaining the Hardware December 2008 2008 Foundry Networks Inc 7 25 AC1 AC2 AC3 AC4 Cord Retainer Cord Retainer...
Страница 148: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 7 34 2008 Foundry Networks Inc December 2008...
Страница 168: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 8 20 2008 Foundry Networks Inc December 2008...
Страница 198: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 C 16 2008 Foundry Networks Inc December 2008...